Q-7.1 NET RADIOMETER
4
3.2 PROGRAMMING EXAMPLE WITH FIXED
WIND SPEED CORRECTION
The following CR10(X) program measures the
output of a Q-7.1. A static wind correction is
applied to each measurement.
Example 1. CR10(X) Program with the
Static Wind Speed Correction
;Measure the Q7.1.
;
01: Volt (Diff) (P2)***
1: 1 Reps
2: 24** ± 250 mV 60 Hz
Rejection Range
3: 1* DIFF Channel
4: 3* Loc [ Rn_W_m2 ]
5: 1 Mult
6: 0 Offset
02: IF (X<=>F) (P89)
1: 3* X Loc [ Rn_W_m2 ]
2: 3 >=
3: 0 F
4: 30 Then Do
;Enter the positive multiplier (p.ppp).
;
03: Z=X*F (P37)
1: 3* X Loc [ Rn_W_m2 ]
2:
p.ppp
F
3: 3* Z Loc [ Rn_W_m2 ]
04: Z=X*F (P37)
1: 3* X Loc [ Rn_W_m2 ]
2: 1.045 F
3: 3* Z Loc [ Rn_W_m2 ]
05: Else (P94)
;Enter the negative multiplier (n.nnn).
;
06: Z=X*F (P37)
1: 3* X Loc [ Rn_W_m2 ]
2:
n.nnn
F
3: 3* Z Loc [ Rn_W_m2 ]
07: End (P95)
* Proper entries will vary with program, and
datalogger channel and input location
assignments.
** On the 21X and CR7 use 500 mV input
range.
*** For a Single-Ended measurement use
Instruction 1.
3.3 PROGRAMMING EXAMPLE WITH DYNAMIC
WIND SPEED CORRECTION
The following CR10(X) program measures an
R. M. Young wind sentry anemometer model
03101 and a Q-7.1. The wind speed is used to
give a real-time wind correction to net
radiation. The wind speed must be measured
before the wind corrections are applied.
Example 2. CR10(X) Program with the
Dynamic Wind Speed Correction
;Measure the 03101 wind sentry.
;
01: Pulse (P3)
1: 1 Reps
2: 1* Pulse Channel 1
3: 21 Low Level AC, Output Hz
4: 1* Loc [ ws_m_s ]
5: .75 Mult
6: .2 Offset
02: IF (X<=>F) (P89)
1: 1* X Loc [ ws_m_s ]
2: 1 =
3: .2 F
4: 30 Then Do
03: Z=F (P30)
1: 0 F
2: 0 Exponent of 10
3: 1* Z Loc [ ws_m_s ]
04: End (P95)
;Measure the Q7.1.
;
05: Volt (Diff) (P2)***
1: 1 Reps
2: 24** ± 250 mV 60 Hz
Rejection Range
3: 1* DIFF Channel
4: 2* Loc [ Rn_mV ]
5: 1 Mult
6: 0 Offset
06: IF (X<=>F) (P89)
1: 2* X Loc [ Rn_mV ]
2: 3 >=
3: 0 F
4: 30 Then Do
;Apply the positive calibration and
;wind speed correction.
;
Kommentare zu diesen Handbüchern