Campbell-scientific SDM-IO16 16-Channel Input/Output Expansion Module Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Hardware Campbell-scientific SDM-IO16 16-Channel Input/Output Expansion Module herunter. Campbell Scientific SDM-IO16 16-Channel Input/Output Expansion Module User Manual [es] Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - Input/Output Expansion Module

SDM-IO16 16 ChannelInput/Output Expansion ModuleRevision: 4/09Copyright © 2002-2009Campbell Scientific, Inc.

Seite 2 - Warranty and Assistance

SDM-IO16 16 Channel Input/Output Expansion Module Minimum frequency: a frequency of 0 Hz is measured if there are less than two high-to-low signal tr

Seite 3

SDM-IO16 16 Channel Input/Output Expansion Module OVFrom sensor510 Ω33 Ω5 V100 KTo internal logic5.6 VO V a) Input biasing and protection 0.6 V DropOu

Seite 4 - Requirements

SDM-IO16 16 Channel Input/Output Expansion Module SDM-IO16DATALOGGER GND12 VSDM-C1 or C1SDM-C2 or C2SDM-C3 or C3 a) Connection with Datalogger Suppl

Seite 5 - SDM-IO16 Table of Contents

SDM-IO16 16 Channel Input/Output Expansion Module Multiple SDM-IO16s can be wired in parallel by connecting the datalogger connections of one SDM-IO16

Seite 6

SDM-IO16 16 Channel Input/Output Expansion Module 5. Address Selection Switches Each SDM-IO16 can have 1 of 16 addresses. The factory-set address is

Seite 7 - Expansion Module

SDM-IO16 16 Channel Input/Output Expansion Module Each SDM-IO16 needs to be set to a unique address on the SDM bus, so that no two SDM peripherals sha

Seite 8 - 2. Specifications

SDM-IO16 16 Channel Input/Output Expansion Module 6.2 CRBasic Programming Dataloggers that use CRBasic include our CR800, CR850, CR1000, CR3000, and

Seite 9

SDM-IO16 16 Channel Input/Output Expansion Module Mode is entered as a four digit parameter, where each parameter indicates the setting for a port. Po

Seite 10

SDM-IO16 16 Channel Input/Output Expansion Module TABLE 2. Bit Period Values Datalogger Default Bit Period Minimum Allowable Bit Period Maximum Bit

Seite 11 - 3. Power Considerations

SDM-IO16 16 Channel Input/Output Expansion Module P188 SDM-IO16 instruction 01:99 SDM address 0-15. 02:9999 Command number 0-255. 03:FP Ports 16-13

Seite 12 - 4. Installation

Warranty and Assistance The SDM-IO16 16 CHANNEL INPUT/OUTPUT EXPANSION MODULE is warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in mat

Seite 13 - 4.1 Terminal Connections

SDM-IO16 16 Channel Input/Output Expansion Module reduction of the SDM-bus speed if the cables are long (see details of P115 in the datalogger manual)

Seite 14

SDM-IO16 16 Channel Input/Output Expansion Module Instruction 29 –used with older CR7s Parameter Type Description 1 2 Reps (No. of modules sequent

Seite 15 - 6.1 General Principles

SDM-IO16 16 Channel Input/Output Expansion Module Pulse counting (1..23): these read the counts accumulated on the specified ports since they were las

Seite 16 - 6.2 CRBasic Programming

SDM-IO16 16 Channel Input/Output Expansion Module Set the interrupt mask (97..98): these commands set a binary mask across the ports to define whether

Seite 17 - 6.2.3 SDMSpeed Instruction

SDM-IO16 16 Channel Input/Output Expansion Module 7. Program Examples 7.1 SDMIO16 Example The following program sets up and measures an SDM-IO16. P

Seite 18 - 6.3 Edlog Programming

SDM-IO16 16 Channel Input/Output Expansion Module Cooling unit: Activate when temperature >27.5°C. Deactivate when temperature <24.5°C. Mixing

Seite 19

SDM-IO16 16 Channel Input/Output Expansion Module ;Call instruction 188 to set the ports as outputs ;with the outputs set low. 2: SDM-IO16 (P188) 1:

Seite 20

SDM-IO16 16 Channel Input/Output Expansion Module 11: If (X<=>F) (P89) ;check upper threshold 1: 1 -- X Loc [ Temp_1 ] ;t

Seite 21

SDM-IO16 16 Channel Input/Output Expansion Module 23: End (P95) ;end 'then do' 24: Else (P94) ;else, if cooler is off 25: Z=F

Seite 22

SDM-IO16 16 Channel Input/Output Expansion Module 36: If time is (P92) ;if 5 minutes remain 1: 10 Minutes (Seconds --) into a ;out of 15 min

Seite 23

IMPORTANT – Please Read First Datalogger Instruction 188 – Software Requirements 1. PC208W Datalogger Support Software PC208W support of SDM-IO16 Ins

Seite 24 - 7. Program Examples

SDM-IO16 16 Channel Input/Output Expansion Module *Table 2 Program 02: 0.0000 Execution Interval (seconds) *Table 3 Subroutines End Program 7.3

Seite 25

SDM-IO16 16 Channel Input/Output Expansion Module ;Measure the four frequencies and write to four input locations ;applying a scaling to m/s 5: SDM-I

Seite 26

SDM-IO16 16 Channel Input/Output Expansion Module ;Maximum windspeeds with time of maximum 11: Maximum (P73) 1: 4 Reps 2: 10 Value with Hr-Min

Seite 27

SDM-IO16 16 Channel Input/Output Expansion Module ; Call instruction 188 to set the ports up 2: SDM-IO16 (P188) 1: 00 SDM Address 2: 90 Command

Seite 28

SDM-IO16 16 Channel Input/Output Expansion Module 28 ;Set the output flag to force immediate storage of data 3: Do (P86) 1: 10 Set Output Flag

Seite 29

Appendix A. General Principles of Pulse and Frequency Measurements A.1 Introduction It is necessary to understand the general method of input measur

Seite 30 - Gauges)

Appendix A. General Principles of Pulse and Frequency Measurements A.3 Resolution of Frequency Measurements The module measures frequency by countin

Seite 31

Appendix A. General Principles of Pulse and Frequency Measurements accurate duty cycle readings for higher frequency signals. Signals up to 4.000 kHz

Seite 32

Appendix A. General Principles of Pulse and Frequency Measurements A-4 The relationship between the minimum debounce time in milliseconds (td) and th

Seite 33

Appendix B. Command Code Listing Command Action 1 Read port 1 accumulated counts into 1 location 2 Read port 2 accumulated counts into 1 location 3

Seite 34

2. CR23X and CR10X Operating System Requirements Use of SDM-IO16 Instruction 188 requires newer datalogger operating systems for the CR23X and CR10X.

Seite 35 - A.1 Introduction

Appendix B. Command Code Listing Command Action 50 Read port 4 duty cycle into 1 location 51 Read port 5 duty cycle into 1 location 52 Read port 6

Seite 36

Appendix B. Command Code Listing Command Action 97 Set interrupt mask of ports 1-16 from 1 location. The location is a 16 bit decimal representation

Seite 37 - A.5 Debounce Filtering

Appendix B. Command Code Listing B-4 This is a blank page.

Seite 39

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbel

Seite 40

SDM-IO16 Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookmarks tab

Seite 41

SDM-IO16 Table of Contents ii Appendices A. General Principles of Pulse and Frequency Measurements ...

Seite 42

SDM-IO16 16 Channel Input/Output Expansion Module The SDM-IO16 (see Figure 1) is a synchronously addressed peripheral. It has 16 ports that can be con

Seite 43

SDM-IO16 16 Channel Input/Output Expansion Module to sixteen SDM-IO16s may be addressed, making it possible to control a maximum of 256 ports from the

Seite 44

SDM-IO16 16 Channel Input/Output Expansion Module Mounting: Mounting brackets have two holes at 225 mm nominal spacing. Mounting screws and plastic i

Kommentare zu diesen Handbüchern

Keine Kommentare