INSTRUCTION MANUAL Model 108 Temperature Probe Revision: 3/14 Copyright © 1985- 2014 Campbell Scientific, Inc.

Seite 2

Model 108 Temperature Probe 8. If LoggerNet, PC400, RTDAQ, or PC200W is running on your PC, and the PC to datalogger connection is active, you can cl

Seite 3 - Limited Warranty

Model 108 Temperature Probe Edlog Polynomial (P55) Linearization Error: <±0.5 °C (–5 to 95 °C) <±0.1 °C (–3 to 90 °C) FIGURE 6-1. Lin

Seite 4 - Assistance

Model 108 Temperature Probe 7. Installation If you are programming your datalogger with Short Cut, skip Section 7.1, Wiring to Datalogger, and Sect

Seite 5 - Table of Contents

Model 108 Temperature Probe outlined in Section 8.3, Electrically Noisy Environments, and Section 8.4, Long Cable Lengths. Details of 108 probe measu

Seite 6 - Figures

Model 108 Temperature Probe Variations: • Temperature reported as °F – add a multiplier (P37) of 1.8 and an offset (P34) of 32 • Ac mains noise filt

Seite 7 - Model 108 Temperature Probe

Model 108 Temperature Probe FIGURE 7-1. 108 and 41303-5A Radiation Shield on a tripod mast FIGURE 7-2. 108 and 41303-5A Radiation Shield on a CM20

Seite 8

Model 108 Temperature Probe 7.4 Water Temperature Installation The 108 can be submerged to 15 m (50 ft) or 21 psi. The 108 is not weighted, so a wei

Seite 9

Model 108 Temperature Probe Vs/Vx = 1000 / (Rs + 40000 Ω + 1000 Ω) Solving for Rs: Rs + 41000 Ω = 1000 • (Vx/Vs) Rs = 1000 • (Vx/Vs) – 41000 Ω TABLE 8

Seite 10 - 6. Specifications

Model 108 Temperature Probe C2 = –40.66 C3 = 16.573 C4 = –3.455 C5 = 0.301 1CRBasic dataloggers are CR800, CR1000, CR3000, and CR5000.

Seite 11

Model 108 Temperature Probe 01: Excite-Delay (SE) (P4) 1: 1 Rep 2: 3 ±25 mV slow range ;CR23X,21X,CR7: 50 mV 3: 9 IN Chan 4: 3

Seite 13 - 7.2.2 Edlog

Model 108 Temperature Probe 9.2 Maintenance The 108 probe requires minimal maintenance. For air temperature measurements, check the radiation shield

Seite 14

Appendix A. Importing Short Cut Code This tutorial shows: • How to import a Short Cut program into a program editor for additional refinement. • H

Seite 15

Appendix A. Importing Short Cut Code 6. Import wiring information to the program by opening the associated .DEF file. Copy and paste the section be

Seite 16 - 8. Operation

Appendix B. Example Programs B.1 Example CRBasic Program This example can be used directly with CR800 series, CR1000, CR3000, and CR5000 datalogger

Seite 17

Appendix B. Example Programs ;{CR10X} ;Program measures one 108 temperature probe once a second ;and stores the average temperature every 60 minutes

Seite 18 - 8.4 Long Cable Lengths

Appendix C. Conversion of Thermistor Resistance or Voltage Ratio to Temperature TABLE C-1. Voltage Ratio, Resistance, and Temperature1 Actual Tempe

Seite 19 - 9.1 Troubleshooting

Appendix C. Conversion of Thermistor Resistance or Voltage Ratio to Temperature 31 75913 1.71 30.95 31.00 32 72569 1.76 31.94 32.00 33 69390 1.81 32.

Seite 20 - 9.3 Calibration

Appendix C. Conversion of Thermistor Resistance or Voltage Ratio to Temperature 87 8523 4.04 87.02 87.00 88 8241 4.06 88.01 88.00 89 7970 4.08 88.99

Seite 21 - A.1.1 CRBasic Datalogger

Appendix C. Conversion of Thermistor Resistance or Voltage Ratio to Temperature C-4

Seite 23 - B.2 Example Edlog Program

Limited Warranty “Products manufactured by CSI are warranted by CSI to be free from defects in materials and workmanship under normal use and service

Seite 24

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbe

Seite 25 - Temperature

Assistance Products may not be returned without prior authorization. The following contact information is for US and international customers residing

Seite 26

Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links to spec

Seite 27

Table of Contents B. Example Programs ... B-1 B.1 Example CRBasic Program ...

Seite 28

Model 108 Temperature Probe 1. Introduction The 108 temperature probe uses a thermistor to measure temperature in air, soil, and water. It is compa