6. Specifications
Features:
IEC Class 1 performance
Low power
High rate of pulses per revolution (up to 13) produced makes it
suitable for wind surveying applications where turbulence is estimated
Compatible Dataloggers: CR10(X)
CR23X
CR800 series
CR1000
CR3000
CR5000
CR9000(X)
Threshold: 0.15 ms
-1
(starting speed 0.2 ms
-1
, stopping
speed 0.1 ms
-1
)
Maximum speed: 77.22 ms
-1
Accuracy: l% ±0.1 ms
-1
Distance Constant: 2.3m ±10%
Calibration Data: Supplied for anemometer and rotor at one test
speed to an accuracy of ±1% at +15°C, 12V
DC supply and an analog output load of 1M
Temperature Range: -30° to +70°C
Height: 19.5 cm (7.68 in.)
Case Diameter: 5.5 cm (2.2 in.)
Rotor: 15.2 cm (6 in.) diameter three-cup rotor
Weight: 490 g (17.3 oz) including 3 m (10 ft) cable
Supply Voltage: 6.5 to 28 Vdc
Current Consumption: 2 mA max., 1.6 mA typical (no output load)
Power-up Time: 5 s
Surge Protection: Vector PC3L2 anti-surge module fitted
6