Campbell-scientific CS547A-L Conductivity/Temperature Probe and A547A Bedienungsanleitung Seite 14

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 30
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 13
CS547A Conductivity and Temperature Probe and A547 Interface
6: BR Transform Rf[X/(1-X)] (P59)
1: 1 Reps
2: 1 Loc [ Rs ]
3: 1 Multiplier (Rf)
7: End (P95)
8: If Case Location < F (P83)
1: 9.25 F
2: 30 Then Do
9: Full Bridge (P6)
1: 1 Reps
2: 15 ±2500 mV Fast Range
3: 1 DIFF Channel
4: 1 Excite all reps w/Exchan 1
5: 2500 mV Excitation
6: 1 Loc [ Rs ]
7: -.001 Mult
8: 1 Offset
10: BR Transform Rf[X/(1-X)] (P59)
1: 1 Reps
2: 1 Loc [ Rs ]
3: 1 Multiplier (Rf)
11: End (P95)
12: If Case Location < F (P83)
1: 280 F
2: 30 Then Do
13: Full Bridge (P6)
1: 1 Reps
2: 14 ±250 mV Fast Range
3: 1 DIFF Channel
4: 1 Excite all reps w/Exchan 1
5: 2500 mV Excitation
6: 1 Loc [ Rs ]
7: -.001 Mult
8: 1 Offset
14: BR Transform Rf[X/(1-X)] (P59)
1: 1 Reps
2: 1 Loc [ Rs ]
3: 1 Multiplier (Rf)
15: End (P95)
16: End (P95)