Campbell-scientific SI-111 (IRR-P) Precision Infrared Radiometer Bedienungsanleitung Seite 1

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Messgeräte Campbell-scientific SI-111 (IRR-P) Precision Infrared Radiometer herunter. Campbell Scientific SI-111 (IRR-P) Precision Infrared Radiometer User Manual [es] Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 18
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
SI-111 Precision
Infrared Radiometer
Revision: 7/13
Copyright © 2002-2013
Campbell Scientific, Inc.,
Apogee Instruments, Inc.
Seitenansicht 0
1 2 3 4 5 6 ... 17 18

Inhaltsverzeichnis

Seite 1 - Infrared Radiometer

SI-111 PrecisionInfrared RadiometerRevision: 7/13 Copyright © 2002-2013Campbell Scientific, Inc.,Apogee Instruments, Inc.

Seite 2

SI-111 Precision Infrared Radiometer 5.1 CR1000 Example Program This example CR1000 program measures the sensor every 5 seconds and outputs a sample

Seite 3 - Warranty

SI-111 Precision Infrared Radiometer 'Instruction to measure mV output of thermopile detector (red wire to 2H, black wire to 2L, clear ‘wire to

Seite 4 - Assistance

SI-111 Precision Infrared Radiometer ;{CR10X} *Table 1 Program 01: 1 Execution Interval (seconds) ;Instruction string to measure the resistance o

Seite 5 - Table of Contents

SI-111 Precision Infrared Radiometer 9: Z=X+F (P34) 1: 8 X Loc [ SB_Temp_K ] 2: -273.15 F 3: 9 Z Loc [ SB_Temp_C ] ;Instruction to

Seite 6

SI-111 Precision Infrared Radiometer ;Target temperature calculation based on m and b coefficients. 15: Z=F x 10^n (P30) 1: 0.4 F 2: 1 n, Ex

Seite 7 - 1. General Description

SI-111 Precision Infrared Radiometer *Table 2 Program 02: 0.0 Execution Interval (seconds) *Table 3 Subroutines End Program 6. Maintenance A pr

Seite 8 - 3. Installation

SI-111 Precision Infrared Radiometer 10

Seite 10 - 5.1 CR1000 Example Program

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbel

Seite 12

Warranty “PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. are warranted by Campbell Scientific, Inc. (“Campbell”) to be free from defects in materi

Seite 13

Assistance Products may not be returned without prior authorization. The following contact information is for US and international customers residing

Seite 14

Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links to spec

Seite 16

SI-111 Precision Infrared Radiometer Prior to November 2008, the SI-111 was named the IRR-P. Only the name changed. NOTE 1. General Description The

Seite 17

SI-111 Precision Infrared Radiometer 3. Installation The field of view for infrared sensors is calculated based on the geometry of the sensor and len

Seite 18

SI-111 Precision Infrared Radiometer 4. Wiring Target Temperature: Red Differential High Black Differential Low Clear Analog Ground Sensor Body T

Kommentare zu diesen Handbüchern