Campbell-scientific 020C Wind Direction Sensor Bedienungsanleitung Seite 13

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 26
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 12
Model 020C Wind Direction Sensor
6. Specifications
Features
Low starting threshold
Internal heater for long bearing life
Low profile to minimize turbulence
High damping ratio
Short delay distance
Quick-disconnect connector
Compatibility
Dataloggers: CR10(X)
CR23X
CR800 series
CR1000
CR3000
Measurement
Range: Electrical 0° to 357°
Mechanical 0° to 360°
Threshold: 0.5 mph
Linearity: ± 0.5% of full scale
Accuracy: ±3°
Damping Ratio: 0.4
Delay Distance: Less than 91 cm (3 ft)
Temperature Range: -50° to 85°C (-58° to 185°F)
Power requirement
Sensor
Source: 12 Vdc
Load: 10 mA
Heater
Source: 12 Vdc
Load: 350 mA
Output: 0 to 5 Vdc for 0 to 360°
(0 to 2.5 Vdc optional)
Output Impedance: 100 maximum
Maximum Cable Length: 300 feet
Weight: 1.5 pounds
Finish: Anodized aluminum
7
Seitenansicht 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 25 26

Kommentare zu diesen Handbüchern

Keine Kommentare