Campbell-scientific BlackGlobe Temperature Sensor for Heat Stress Bedienungsanleitung Seite 29

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 32
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 28
Appendix B. Edlog Programming Examples
TABLE B-2. Actual Temperature, Sensor
Resistance, and Computed Temperature
Temperature
°C
Resistance
OHMS
Output
°C
74.00 13405 73.98
76.00 12479 75.99
78.00 11625 78.01
80.00 10837 80.02
82.00 10110 82.03
84.00 9438.1 84.04
86.00 8816.9 86.03
88.00 8241.9 88.00
90.00 7709.7 89.96
92.00 7216.3 91.89
94.00 6758.9 93.80
96.00 6334.5 95.67
98.00 5940.5 97.51
100.00 5574.3 99.31
B.2 Edlog Programming for Long Lead Lengths
The following is a portion of an example CR10X program that uses the Excite-
Delay (SE) (P4) instead of the AC Half Bridge (P5).
01: Excite, Delay,Volt(SE) (P4)
1: 1 Rep
2: 3 ±25 mV slow range ;On the 21X and CR7 use the 50 mV input range.
3: 1 IN Chan ;Entry depends on the datalogger SE channel used
4: 1 Excite all reps w/EXchan 3 ;Entry depends on the excitation channel used
5: 2 Delay (units .01sec)
6: 1000 mV Excitatio ;On the 21X and CR7 use the 2000 mV excitation
7 1 Loc [BGTemp_C ]
8: .2 Mult ;Use a multiplier of 0.1 with a 21X or CR7
9: 0 Offset
B-9
Seitenansicht 28
1 2 ... 24 25 26 27 28 29 30 31 32

Kommentare zu diesen Handbüchern

Keine Kommentare