EnviroSMART
TM
Soil Water Content Profile Probes
7: If (X<=>F) (P89)
1: 1 X Loc [ ES1_SF_1 ]
2: 2 <>
3: 0 F
4: 31 Exit Loop if True
8: End (P95)
;Measure salinity volumetric ion content (VIC)
9: Beginning of Loop (P87)
1: 0 Delay
2: 5 Loop Count
10: SDI-12 Recorder (P105)
1: 0 SDI-12 Address
2: 2 Start Measurement (aM2!)
3: 7 Port
4: 17 Loc [ ES1_VIC_1 ]
5: 1.0 Mult
6: 0 Offset
11: If (X<=>F) (P89)
1: 17 X Loc [ ES1_VIC_1 ]
2: 2 <>
3: 0 F
4: 31 Exit Loop if True
12: End (P95)
;Load measurement failure errors
13: If (X<=>F) (P89) ;Measurement of 0 at 1st sensor
1: 1 X Loc [ ES1_SF_1 ] ;indicates an inactive probe.
2: 1 = ;
3: 0 F
4: 30 Then Do
14: Z=F x 10^n (P30) ;Set 1st sensor reading to -99999
1: -99999 F
2: 0 n, Exponent of 10
3: 1 Z Loc [ ES1_SF_1 ]
15: End (P95)
16: Beginning of Loop (P87) ;Loop to set error codes
1: 0 Delay
2: 8 Loop Count
10