Campbell-scientific IRGASON Integrated CO2/H2O Open-Path Gas Analyzer Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Messgeräte Campbell-scientific IRGASON Integrated CO2/H2O Open-Path Gas Analyzer herunter. Campbell Scientific IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - INSTRUCTION MANUAL

INSTRUCTION MANUAL IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer Revision: 6/14 Copyright © 2

Seite 2

Table of Contents iv

Seite 3 - Limited Warranty

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer 1. Introduction The IRGASON, U.S. Des. Patent No. D680455, is an in-situ,

Seite 4 - Assistance

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer o The SDM, USB, and RS-485 output options include IRGASON diagnostic data.

Seite 5 - Precautions

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer These measurements are required to compute carbon dioxide and water vapor f

Seite 6

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer Sonic accuracy5 Offset error ux, uy: < ±8 cm·s–1 uz: < 4 cm·s–1 Ga

Seite 7

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer 5.2 Output Signals Features • EC100 electronics outputs data using: o CS

Seite 8

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer FIGURE 5-1. IRGASON dimensions, side view FIGURE 5-2. IRGASON dimension

Seite 9

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer 5.4 Power Requirements During Power-up and Operation Power requirement Sou

Seite 10 - Table of Contents

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer Handle the IRGASON carefully. The optical source may be damaged by rough h

Seite 11 - 2. Cautionary Statements

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer FIGURE 6-1. Exploded view of mounting the IRGASON Over-tightening bolts w

Seite 13

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer FIGURE 6-2. EC100-enclosure mounting bracket mounted on a ver

Seite 14

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer 8. Mount the IRGASON temperature probe so that it measures temperature at

Seite 15 - 5.3 Physical Description

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer 2. Connect the IRGASON sonic cable. Similar to (a), begin by removing the

Seite 16

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer FIGURE 6-6. Base of EC100 enclosure Unique calibration information is st

Seite 17 - 6. Installation

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer 3. Connect the IRGASON temperature probe. Unscrew the temperature connect

Seite 18

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer o Analog output: use cable CABLE4CBL-L (pn 21972) or CABLE2TP-L (pn 26986-

Seite 19

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer 7.1 Factory Defaults TABLE 7-1 shows the default value for each setting de

Seite 20

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer any integer value between 0 and 14. The value 15 is reserved as an SDM-grou

Seite 21 - 6.3 Wiring and Connections

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer 7.11 Pressure Sensor This setting identifies which barometric pressure sen

Seite 22

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer The algorithm uses the internal heaters to maintain a temperature that is a

Seite 23

Limited Warranty “Products manufactured by CSI are warranted by CSI to be free from defects in materials and workmanship under normal use and service

Seite 24

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer Besides changing settings, ECMon is a useful tool for common tasks such as:

Seite 25 - 7. Settings

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer FIGURE 7-2. Setup window in ECMon 7.15 Device Configuration Utility DevC

Seite 26 - 7.3 SDM Address

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer 8. EC100 Outputs The EC100 is the IRGASON electronics module that measures

Seite 27

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer To use USB or RS-485 output, connect a USB or RS-485 cable from the EC100 t

Seite 28 - 7.13 Heater Control

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer The final data element in each row or output array is the signature. The s

Seite 29 - 7.14 ECMon

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer TABLE 8-2. Multipliers and Offsets for Analog Outputs Density (mg m-3) Vol

Seite 30

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer Wick Spares Kit (pn 28902) consists of three top wicks, three bottom wicks,

Seite 31

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer 9.2.2 Gas Analyzer Wicks IRGASON gas analyzer windows are polished and sla

Seite 32 - 8. EC100 Outputs

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer FIGURE 9-3. Proper location of the gas analyzer top wick (left) and

Seite 33

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer The first part of the following procedure simply measures the CO2 and H2O z

Seite 34 - 8.3 Analog Outputs

Assistance Products may not be returned without prior authorization. The following contact information is for US and international customers residing

Seite 35 - 9. Maintenance

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer FIGURE 9-4. The zero-and-span shroud mounted on the zero-and-span stand.

Seite 36

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer Use mixtures of CO2 and ambient air for the CO2 span gas. The use of refer

Seite 37 - 9.2.2 Gas Analyzer Wicks

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer 11. Examine the measurements that were written down for span CO2, span H2O

Seite 38 - 9.4 Zero and Span

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer excessively (see Section 9.4, Zero and Span), the bottles should be replace

Seite 39

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer Monitoring Division / National Oceanographic and Atmospheric Administration

Seite 40

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer TABLE 10-1. Output Modes for EC100 Instruction Output Mode Data Field Des

Seite 41

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer TABLE 10-3. Bits in the Gas Diagnostic Flag bit hex value decimal Na

Seite 42

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer 10.2 EC100Configure() Instruction EC100Configure() provides a third option

Seite 43 - 9.6 Factory Recalibration

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer TABLE 10-4. Config Cmd Values for Setting and Retrieving Settings ConfigC

Seite 44 - 10. Datalogger Programming

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer 10.2.1 ConfigCmd 11 Zero-and-span Control To perform zeroing of CO2 and H2O

Seite 45

Precautions DANGER — MANY HAZARDS ARE ASSOCIATED WITH INSTALLING, USING, MAINTAINING, AND WORKING ON OR AROUND TRIPODS, TOWERS, AND ANY ATTACHMENTS TO

Seite 46

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer output indicates moisture is present, the datalogger can send the EC100Conf

Seite 47

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer 11. Theory of Operation 11.1 IRGASON Sonic Anemometer The CSAT3 measures

Seite 48

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer 11.1.2 Temperature The sonically determined speed of sound can be found fro

Seite 49

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer The sonic virtual temperature, in degrees Celsius, is given by Eq. (9), whe

Seite 50

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer 11.3 Theory References Kaimal, J. C. and Businger, J. A.: 1963, “A Contin

Seite 51 - 11. Theory of Operation

Appendix A. Filter Bandwidth and Time Delay The EC100 measures CO2, H2O, 3-D wind components, and sonic temperature from the IRGASON at 100 Hz and t

Seite 52 - 11.1.2 Temperature

Appendix A. Filter Bandwidth and Time Delay The EC100 measures gas and wind data at 100 Hz, and 100 Hz data are down-sampled to the datalogger scan r

Seite 53 - 11.2 IRGASON Gas Analyzer

Appendix A. Filter Bandwidth and Time Delay FIGURE A-2. Frequency response comparison of the EC100 10 Hz bandwidth and a 50 ms moving average TABLE

Seite 54 - 11.3 Theory References

Appendix A. Filter Bandwidth and Time Delay A-4

Seite 55

Appendix B. Equations TABLE B-1 lists variables and constants used in the following equations. TABLE B-1. Table of Equation Variables and Constants

Seite 57

Appendix B. Equations ( )+−+=vvddXXTRPM1000115.273ρ (B-5) Dew Point from Molar Mixing Ratio tmpdtmpddTTT__502.17 97.240−= (B-62) (

Seite 58

Appendix C. Material Safety Data Sheets (MSDS) MSDS are available for chemicals used in IRGASON filters. The MSDS samples below are made available

Seite 59 - Appendix B. Equations

Appendix C. Material Safety Data Sheets (MSDS) C.2 Decarbite MSDS C-2

Seite 60

Appendix C. Material Safety Data Sheets (MSDS) C-3

Seite 61 - Sheets (MSDS)

Appendix C. Material Safety Data Sheets (MSDS) C-4

Seite 63

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbe

Seite 64

Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links to spec

Seite 65

Table of Contents 9. Maintenance ..... 25 9.1 Routine Maintenance ...

Seite 66

Table of Contents 9-1. Proper location of the sonic top wick (left) and bottom wick (right) ..............