DCP100 DATA COLLECTION PLATFORM
11
9.1.2 Datalogger Programming Theory
Campbell Scientific dataloggers are
programmed via a keyboard/display or an IBM-
PC compatible computer running PC208
software. Please see the appropriate
datalogger manual for detailed programming
information.
To transmit two different arrays the datalogger's
program must have this structure:
Set Output Flag 0 high (10) based on condition 1
Output Processing Instructions
Conditional Statement; if true “Then Do”
(Command Code 30)
P120 Data transfer to TGT1
Set Output Flag 0 high (10) based on
condition 2
Output Processing Instructions
Conditional Statement; if true “Then Do”
(Command Code 30)
P120 Data Transfer to TGT1
Table 9.1-2 illustrates the correct programming
structure.
TABLE 9.1-2 CR10X Example Program
This example makes a thermocouple and
battery voltage measurement and sends data to
the TGT1's buffer only when the CR10X
generates an output.
NOTE: Use a conditional statement (i.e.,
Instruction 92) to transfer data only when
there is an output to final storage.
;
*Table 1 Program
01: 10.0 Execution Interval
(seconds)
;Measure reference temperature.
01: Internal Temperature (P17)
1: 1 Loc [ RefTemp ]
;Measure thermocouple temperature.
02: Thermocouple Temp (DIFF) (P14)
1: 1 Reps
2: 1 ± 2.5 mV Slow Range
3: 5 DIFF Channel
4: 1 Type T (Copper-Constantan)
5: 1 Ref Temp Loc [ RefTemp ]
6: 2 Loc [ TCDeg_C ]
7: 1 Mult
8: 0 Offset
;Measure battery voltage every 10 seconds.
03: Batt Voltage (P10)
1: 3 Loc [ Battery ]
;Set Output Flag High (10) for hourly data (user
defined).
04: If time is (P92)
1: 0 Minutes (Seconds --) into a
2: 60 Interval (same units as above)
3: 10 Set Output Flag High
;Timestamp data
05: Real Time (P77)
1: 220 Day,Hour/Minute (prev day
at midnight, 2400 at
midnight)
;Output hourly the average reference Temp, TC
Temp, and battery voltage.
06: Average (P71)
1: 3 Reps
2: 1 Loc [ RefTemp ]
;Sample the forward and reflected power.
07: Sample (P70)
1: 2 Reps
2: 4 Loc [ FwdPwr ]
;Transfer data to TGT1 every hour.
08: If time is (P92)
1: 0 Minutes (Seconds --) into a
2: 60 Interval (same units as
above)
3: 30 Then Do
;Transfer datalogger's final storage data to the
TGT1, read the transmitter's latest forward and
reflected power readings, and place the results
in two sequential input locations.
09: Data Transfer to GOES (P120)
1: 00 Buffer Selection
2: 4 FWD/Ref Power Loc
[ FwdPwr ]
10: End (P95)