INSTRUCTION MANUAL
LoggerNet
Version 4.2
Revision: 7/14
Copyright © 1999- 2014
Campbell Scientific, Inc.
Seitenansicht 0
1 2 3 4 5 6 ... 579 580

Inhaltsverzeichnis

Seite 1 - INSTRUCTION MANUAL

INSTRUCTION MANUAL LoggerNet Version 4.2 Revision: 7/14 Copyright © 1999- 2014 Campbell Scientific, Inc.

Seite 2

Table of Contents 7.3.3.8.1 Editor Preferences ... 7-33 7.3.3.8.2 Instruction Panel Preferences ...

Seite 3 - License for Use

Section 4. Setting up Datalogger Networks Advanced Extra Response Time – The amount of additional time, in seconds, that LoggerNet should wait for th

Seite 4 - Limited Warranty

Section 4. Setting up Datalogger Networks If you are using LoggerNet Admin or LoggerNet Remote 4.0 and using the Connect Screen to connect to a remot

Seite 5 - Table of Contents

Section 4. Setting up Datalogger Networks Routing Tab Outbound PakBus Connections This box is used to specify IP addresses and port numbers for outbo

Seite 6

Section 4. Setting up Datalogger Networks When configuring a SerialPortPool, use the Serial Ports tab to add all the serial ports that are connected

Seite 7

Section 4. Setting up Datalogger Networks Maximum Time On-Line – Enter a time limit for maintaining a connection to the device. (This may be useful

Seite 8

Section 4. Setting up Datalogger Networks All of the COM ports which are set up and recognized by Windows will be shown in the Available Ports list.

Seite 9

Section 4. Setting up Datalogger Networks When configuring a TerminalServerPool, use the Terminal Servers tab to add all the terminal servers that a

Seite 10

Section 4. Setting up Datalogger Networks period of time.) Maximum Time On-Line applies to both scheduled connections and manual connections. Howev

Seite 11

Section 4. Setting up Datalogger Networks To add a terminal server to the pool, type in the address of the terminal server port in the Terminal Serve

Seite 12

Section 4. Setting up Datalogger Networks Table Data Dataloggers When connected, data from table data dataloggers is updated based on the Update Inte

Seite 13

Table of Contents 7.4.8 Repetitions ... 7-68 7.4.9 Input Location Editor

Seite 14

Section 4. Setting up Datalogger Networks If data collection is enabled for input location data (Inlocs) on the CR10X-TD/PB family dataloggers or Pu

Seite 15

Section 4. Setting up Datalogger Networks You should check the directory path and the data file options to make sure the files are where you want the

Seite 16

Section 4. Setting up Datalogger Networks 4.2.6 Setting the Clock A datalogger’s Clock tab can be used to define a schedule at which an automatic cl

Seite 17

Section 4. Setting up Datalogger Networks 4.2.7 Sending a Program to the Datalogger from Setup In most instances, you will send a new program to the

Seite 18

Section 4. Setting up Datalogger Networks Data File Settings This box is used to set a maximum size, in bytes, for data files. When the maximum file

Seite 19 - Product History

Section 4. Setting up Datalogger Networks 17338. However, if a firewall is in use, the port value may be changed when passed through the firewall. T

Seite 20

Section 4. Setting up Datalogger Networks This dialog box allows you to copy setting(s) from the device currently selected in the network map to othe

Seite 21

Section 4. Setting up Datalogger Networks Press the New Subnet button to add a new subnet. You will be asked to enter a name for the subnet. All o

Seite 22 - LoggerNet Products

Section 4. Setting up Datalogger Networks 4.3 Network Planner The Network Planner is a graphical application that assists you in designing PakBus da

Seite 23 - Setup Screen

Section 4. Setting up Datalogger Networks 4.3.2.1 Adding a Background Image A background image can be associated with the model by using the Option

Seite 24 - Task Master

Table of Contents 8.1.7.3.1 Selecting Data to be Plotted ... 8-23 8.1.7.3.2 XY Plot Toolbar ...

Seite 25 - CRBasic Editor

Section 4. Setting up Datalogger Networks Using the Scroll Buttons Navigation buttons that can be used to scroll the model canvas are highlighted in

Seite 26

Section 4. Setting up Datalogger Networks Using the Mouse While the Hand Tool is selected by pressing the hand icon on the toolbar, you can scroll th

Seite 27 - View Pro

Section 4. Setting up Datalogger Networks You must select the communication interface for the new peripheral from the dialog list box. These interfa

Seite 28

Section 4. Setting up Datalogger Networks When the canvas is operating in this mode, the mouse cursor changes from a hand to a jagged line. While in

Seite 29

Section 4. Setting up Datalogger Networks In this instance, for radio based links, the icon is a small yagi antenna. If you hover the mouse cursor o

Seite 30

Section 4. Setting up Datalogger Networks Aside from providing a means of documentation, activities in the Network Planner model serve an important r

Seite 31 - 1.1 Hardware and Software

Section 4. Setting up Datalogger Networks Source Device – Specifies the device that will initiate the activity. This choice box will be populated wit

Seite 32

Section 4. Setting up Datalogger Networks 4.3.7 The Station Summary The station summary is a view that displays details about the station that is c

Seite 33 - Backup Procedures

Section 4. Setting up Datalogger Networks • An optional link to perform the Configure Devices list item for the device. • A description of any acti

Seite 34 - 2.2 Upgrade Notes

Section 4. Setting up Datalogger Networks and provides check-boxes that allow these items to be checked off to indicate when an item has been complet

Seite 35 - 2.3.1.2 Working Directories

Table of Contents 8.2.6.3.1 Input/Output File Command Line Switches for Processing Alternate Files ... 8-83 8.2.6.4 Processing

Seite 36

Section 4. Setting up Datalogger Networks Connect – When clicked, this button will disable the dialog controls and initiate communication with the de

Seite 37

Section 4. Setting up Datalogger Networks This dialog allows you to specify a user name and password for an administrative account on the local serve

Seite 38

Section 4. Setting up Datalogger Networks This dialog has the following controls: Model Prefix – This field allows you to enter a string that will b

Seite 39

Section 4. Setting up Datalogger Networks Help Window – The HTML window in the upper right corner of the dialog shows context sensitive help about th

Seite 40 - 2.3.4 Program Crashes

Section 4. Setting up Datalogger Networks The colors of items in this dialog indicate the impact they may have on the operation of devices that are a

Seite 41 - 2.4.1.1 Write Access

Section 4. Setting up Datalogger Networks 4.3.10 Arranging Screen Components The Network Planner user interface has been designed so that you can ex

Seite 42 - 2.4.1.2 Network Drives

Section 4. Setting up Datalogger Networks 4-80

Seite 43

Section 5. Real-Time Tools LoggerNet’s real-time tools are used to manage your stations in the datalogger network. Tools are provided for sending n

Seite 44

Section 5. Real-Time Tools As noted above, you can work with a datalogger station while actively connected to it or when you are in a disconnected s

Seite 45 - Section 3. Introduction

Section 5. Real-Time Tools Once the datalogger connection is established, an elapsed time for the connection will be shown on the bottom left of the

Seite 46 - 3.2.1.1 Toolbar Views

Table of Contents 10.3.3.5 Data Tab ... 10-18 10.3.4 Deleting a Station ...

Seite 47 - 3.2.1.2 Favorites Category

Section 5. Real-Time Tools Once you have started data collection with Collect Now, you can stop it by clicking the Cancel button on the animated scre

Seite 48 - 3.2.1.3 Toolbar Menus

Section 5. Real-Time Tools − Collect All Since Last Collection – When this option is selected, LoggerNet will attempt to collect all the data since

Seite 49

Section 5. Real-Time Tools While retrieving data from the datalogger using Custom Collection, scheduled data collection will be suspended. The defau

Seite 50

Section 5. Real-Time Tools − Data Since Last Collection will retrieve the data stored since the last time a custom collection was performed. Logger

Seite 51 - 3.2.4 Real Time Tools

Section 5. Real-Time Tools When the Don’t Quote Strings check box is selected, strings in the data will not be surrounded by quotation marks. If the

Seite 52

Section 5. Real-Time Tools Different datalogger models have a different number of ports and flags. The Ports and Flags dialog box will display only

Seite 53

Section 5. Real-Time Tools A control port must first be configured for output in the datalogger program before it can be toggled on or off. Conseque

Seite 54 - 3.2.11.1 LoggerNetData

Section 5. Real-Time Tools 5.1.5 Program Management The Program section on the Connect Screen is used to send programs to or retrieve programs from

Seite 55 - 3.2.11.3 Baler

Section 5. Real-Time Tools 5.1.5.2 CR200 Series Programs Programs for the CR200 Series dataloggers must be precompiled before being sent to the data

Seite 56

Section 5. Real-Time Tools after associating the file, you may need to recompile the program file with a version of Edlog that stores this informatio

Seite 57 - Networks

Table of Contents 13. Implementing Advanced Communications Links ... 13-1 13.1 Pho

Seite 58

Section 5. Real-Time Tools If clock updates and display updates are paused while connected to a datalogger, the connection may time out and terminate

Seite 59

Section 5. Real-Time Tools 5.1.7.2.1 Adding and Removing Values The Numeric Display is initially blank when opened; the fields to be displayed must

Seite 60

Section 5. Real-Time Tools Selecting a table name or final storage array ID will bring up a list of data fields in the right hand window. Select th

Seite 61

Section 5. Real-Time Tools To delete data fields from the Numeric Display, select the data fields on the display and press the Delete button. You ca

Seite 62

Section 5. Real-Time Tools Alarms Tab Enable Alarms – Alarms can be set to turn the background of a field a different color depending on the value of

Seite 63 - 4.2.4 Device Settings

Section 5. Real-Time Tools A mixed-array datalogger’s final storage data must be collected by LoggerNet before it can be displayed. When a value de

Seite 64

Section 5. Real-Time Tools Table-based dataloggers – If the Add Selection dialog box is empty, return to the Setup Screen’s Data Files table and se

Seite 65

Section 5. Real-Time Tools Scaling Tab The Scaling options has tabs to set up the scale for the left and right axes. The axes can be scaled automati

Seite 66

Section 5. Real-Time Tools value is less than –10, all of the points in the series are divided by 10 until the maximum value is less than or equal to

Seite 67 - 4.2.4.4 Datalogger

Section 5. Real-Time Tools Visual Display Tab The Visual Display options allow the user set the appearance of the graph. The colors for the grids a

Seite 68

Table of Contents B.1.5 TOB1 ... B-4 B.1.6 Array Compatible CSV

Seite 69

Section 5. Real-Time Tools Display Options – These options are used to set the look of the graph itself. The Background Color selects the color of t

Seite 70

Section 5. Real-Time Tools Plot NAN as value – With this option is selected, each NAN value in the data will be represented by the specified value. C

Seite 71

Section 5. Real-Time Tools Display Tab Color – Sets the color of the trace and the data points. The user can choose from the Windows color palette f

Seite 72

Section 5. Real-Time Tools Save As – Allows you to save a picture of the current graph in a BMP or WMF format. Copy – Save a copy of the current grap

Seite 73

Section 5. Real-Time Tools Trace Options – Displays a dialog box that lets you set the color and appearance of the trace. Help – Brings up help for

Seite 74

Section 5. Real-Time Tools 5.1.9 File Control for CR5000, CR1000, CR800 Series, CR3000, and CR9000 Dataloggers CR5000, CR1000, CR3000, CR800 Series,

Seite 75

Section 5. Real-Time Tools modified and the file attributes which indicate whether the file is Read Only (R) or Read/Write (RW). Note that the Size,

Seite 76

Section 5. Real-Time Tools CR1000/CR3000/CR800 Series Datalogger Run Now Options When Run Now is checked, the program is compiled and run in the dat

Seite 77

Section 5. Real-Time Tools To summarize, any change in data table structure will delete all tables on the datalogger’s CPU, regardless of whether or

Seite 78

Section 5. Real-Time Tools CR1000, CR3000, and CR800 Series Dataloggers — A program marked as “Run on power up” can be disabled when power is first a

Seite 79 - 4.2.4.5 PhoneBase

Table of Contents E. Log Files ... E-1 E.1 Event Logging ...

Seite 80 - 4.2.4.6 PhoneRemote

Section 5. Real-Time Tools To activate the remote keyboard select Datalogger | Terminal Emulator from the menu. The remote terminal mode should be us

Seite 81 - 4.2.4.7 RFBase

Section 5. Real-Time Tools Only the summary tab is available for array-based dataloggers. The Table Fill Times tab lists the tables in the datalogger

Seite 82 - 4.2.4.8 RFRemote

Section 5. Real-Time Tools FieldCalStrain instruction are zeroing, 1/4 bridge strain shunt, bending 1/2 bridge strain shunt, and bending full bridge

Seite 83 - 4.2.4.9 RFBase-TD

Section 5. Real-Time Tools RTMC was designed to be easy and straightforward to use. Experiment with different combinations and options to get the di

Seite 84

Section 5. Real-Time Tools 5.2.1.2 Display Components Display components are the objects that are used to display data. To add a component to the w

Seite 85

Section 5. Real-Time Tools Label displays a text string that can be used to label other components. Switch indicates the state of a port, flag, in

Seite 86

Section 5. Real-Time Tools File Menu New Project starts a new RTMC project. The currently opened project will be closed. If there are changes that

Seite 87 - 4.2.4.11 RFRemote-PB

Section 5. Real-Time Tools data value changes, and specify whether high quality or high speed is more important. (Disabling animation disables the sm

Seite 88 - 4.2.4.12 MD9 Base

Section 5. Real-Time Tools number is 6789. Note that the remote LoggerNet server must have Remote Connections enabled (Tools | Options | Allow Remot

Seite 89

Section 5. Real-Time Tools Cut deletes the selected component and places a copy on the Windows clipboard. Copy places a copy of the selected componen

Seite 90 - 4.2.4.13 MD9 Remote

Table of Contents 8-3. Processed Data File Using Option C ... 8-51 8-4. Input File Entries to Process the

Seite 91 - 4.2.4.14 RF400

Section 5. Real-Time Tools When components are grouped, the properties for each of the components will show up as an item in the Component right-clic

Seite 92 - 4.2.4.15 RF400 Remote

Section 5. Real-Time Tools StartRelativeToNewest(nsecPerDay,ordercollected); MaxRunOverTime(“Server:CR1000.QtrHour.Temp”,Timestamp(“Server:CR1000.Qtr

Seite 93

Section 5. Real-Time Tools Timestamps are truncated to seconds prior to synchronization. Therefore, synchronizing sub-second data is not recommended

Seite 94 - 4.2.4.16 Generic Modem

Section 5. Real-Time Tools 5.2.1.4.2 Order of Precedence When processing mathematical expressions, the order of precedence is: • Anything inside pa

Seite 95 - 4.2.4.17 PakBusPort

Section 5. Real-Time Tools nsecPerDay Number of nanoseconds in a day nsecPerWeek Number of nanoseconds in a week 5.2.1.4.5 Functions The following f

Seite 96

Section 5. Real-Time Tools Function Description LOG(x) Returns the natural log of a number. (Note that LN or LOG may be used to perform the same fun

Seite 97

Section 5. Real-Time Tools 5.2.1.4.7 String Functions Function Description Hex Returns a hexadecimal string representation of an expression. HexToDe

Seite 98 - 4.2.4.18 PakBus Router

Section 5. Real-Time Tools 5.2.1.4.9 Time Functions Function Description FormatTime Produces a string that formats a timestamp in the manner specifi

Seite 99 - 4.2.4.19 PakBusPort HD

Section 5. Real-Time Tools 5.2.1.4.11 Statistical Functions Function Description AvgRun Returns a running average of up to the last specified number

Seite 100 - 4.2.4.20 PakBusTcpServer

Section 5. Real-Time Tools Function Description StdDevOverTimeWithReset Returns the standard deviation of the specified value since the function was

Seite 101

Preface — What’s New in LoggerNet 4? Product History LoggerNet 4 continues the original design of client-server functionality that first appeared whe

Seite 102 - 4.2.4.21 SerialPortPool

Section 5. Real-Time Tools and Run Project menu or clicking the Run-Time icon on the toolbar. This will start the project window with RTMC Run-Time

Seite 103

Section 6. Network Status and Resolving Communication Problems LoggerNet provides several tools for monitoring the status of a datalogger network an

Seite 104

Section 6. Network Status and Resolving Communication Problems 6.1.1 Visual Status Indicators There are three visual status indicators in the first

Seite 105 - 4.2.4.22 TerminalPortPool

Section 6. Network Status and Resolving Communication Problems where failures = number of communication failures retries = number of communicati

Seite 106

Section 6. Network Status and Resolving Communication Problems Entries in the Available Columns field will not be displayed on the main screen. Entr

Seite 107

Section 6. Network Status and Resolving Communication Problems Primary Retry – A data collection failure has led to the primary retry collection sch

Seite 108

Section 6. Network Status and Resolving Communication Problems last clock check was performed. If the datalogger clock is slower than the computer c

Seite 109 - 4.2.5.2 Intervals

Section 6. Network Status and Resolving Communication Problems • Memory Code (Mem Code) – (Array-based dataloggers only) This number is an indicatio

Seite 110

Section 6. Network Status and Resolving Communication Problems • Total Retries – The total number of communication attempts with a device after the

Seite 111

Section 6. Network Status and Resolving Communication Problems a lot of uncollected data and it would take too long to get it all. These functions a

Seite 113 - 4.2.8 Setup’s Tools Menu

Preface — What’s New in LoggerNet 4? PakBus network, proposes and verifies valid connections between devices, and allows integration of the model dire

Seite 114

Section 6. Network Status and Resolving Communication Problems 6.1.2.7 Pool Devices The Tools | Pool Devices menu item opens a new window that offe

Seite 115

Section 6. Network Status and Resolving Communication Problems Column Descriptions Device Name – Indicates the name of the device associated with th

Seite 116 - 4.2.11 Selecting a View

Section 6. Network Status and Resolving Communication Problems Remove Operations When Finished When this check box is selected (default), operations

Seite 117

Section 6. Network Status and Resolving Communication Problems 6.2.1 Log Types Transaction Log (tran$.log) – This log includes information on the tr

Seite 118 - 4.3 Network Planner

Section 6. Network Status and Resolving Communication Problems I/O Log – Opens the Low Level I/O log for a specific COM port in a new window. TimeSt

Seite 119

Section 6. Network Status and Resolving Communication Problems The following settings are used to save the logs to disk as well as to control the num

Seite 120

Section 6. Network Status and Resolving Communication Problems When you first open Comm Test, the state of the devices is unknown, so the circles for

Seite 121

Section 6. Network Status and Resolving Communication Problems 6.4.1 Selecting the PakBus Network to View When PakBus Graph is opened, it is set to

Seite 122 - 4.3.5 Adding Stations Links

Section 6. Network Status and Resolving Communication Problems 6.4.4 Right-Click Functionality There are several options available from the floating

Seite 123

Section 6. Network Status and Resolving Communication Problems devices in its communications link. If Datalogger Network is highlighted, the status

Seite 124 - 4.3.6 Adding Activities

Preface — What’s New in LoggerNet 4? can choose to view a subnet rather that the entire network in the Setup Screen, Connect Screen, and Status Monito

Seite 125

Section 6. Network Status and Resolving Communication Problems Scheduled Collection – This is the automatic data collection schedule. The state is e

Seite 126

Section 6. Network Status and Resolving Communication Problems The left-hand pane of the TD-RF Quality Test window displays the network map as config

Seite 127 - 4.3.7 The Station Summary

Section 6. Network Status and Resolving Communication Problems Back 2T – Applicable only to an RF Link Quality test, this is the maximum transition p

Seite 128 - 4.3.8 Configuring Devices

Section 6. Network Status and Resolving Communication Problems Clear – Clicking this button clears the contents of the right-hand pane. Start Test –

Seite 129

Section 6. Network Status and Resolving Communication Problems LoggerNet responds by sending an RF Test command packet, containing a definition of th

Seite 130

Section 6. Network Status and Resolving Communication Problems The information recorded in the TD-RF Quality Report includes the location of the max

Seite 131

Section 6. Network Status and Resolving Communication Problems modem acknowledge the reception of an RF Test Packet. If the sending modem does not re

Seite 132

Section 6. Network Status and Resolving Communication Problems 6.5.5 Other Tools in Troubleshooter Other network status tools can be launched from t

Seite 133

Section 6. Network Status and Resolving Communication Problems (white background/red text) The LoggerNet server is no longer running. If Warnings

Seite 134 - 4.3.9 Saving Your Work

Section 7. Creating and Editing Datalogger Programs Datalogger must be programmed before they can make measurements. LoggerNet offers three options

Seite 135

Preface — What’s New in LoggerNet 4? A Constant Customization feature has been added to the CRBasic Editor. This allows you to define values for one o

Seite 136

Section 7. Creating and Editing Datalogger Programs way, but store the processed data in individual tables instead of arrays. Each final storage tab

Seite 137 - Section 5. Real-Time Tools

Section 7. Creating and Editing Datalogger Programs Short Cut was designed with extensive built-in help. Help can be accessed at any time by pressin

Seite 138

Section 7. Creating and Editing Datalogger Programs 7.2.2.2 Step 2 – Select Datalogger and Specify Scan Interval Click the arrow next to Datalogger

Seite 139 - 5.1.2 Data Collection

Section 7. Creating and Editing Datalogger Programs From this box, you indicate which CR9000X modules are inserted into which CR9000X slots. To add

Seite 140 - 5.1.2.2 Custom Collection

Section 7. Creating and Editing Datalogger Programs This setting is similar to the Integration setting in that the dialog box will be displayed only

Seite 141

Section 7. Creating and Editing Datalogger Programs 7.2.2.3 Step 3 – Choose Sensors to Monitor In step 3, you tell Short Cut which sensors you’ll be

Seite 142

Section 7. Creating and Editing Datalogger Programs Note that this sensor not only offers a custom name field and units, but also allows you to corr

Seite 143

Section 7. Creating and Editing Datalogger Programs 7-9

Seite 144 - 5.1.3 Ports and Flags

Section 7. Creating and Editing Datalogger Programs Click on the Wiring tab of a sensor’s parameter form to show the wiring for the sensor (or the fi

Seite 145

Section 7. Creating and Editing Datalogger Programs In addition to actual sensors, Short Cut provides functionality to perform various calculations a

Seite 146 - 5.1.4 Datalogger Clock

Preface — What’s New in LoggerNet 4? Setup Screen The Setup Screen now has the option of being used in an EZ View or a Standard View. The Standard Vi

Seite 147 - 5.1.5 Program Management

Section 7. Creating and Editing Datalogger Programs Short Cut provides you with a wiring diagram by clicking on Wiring Diagram on the left side of th

Seite 148 - 5.1.6 Program Association

Section 7. Creating and Editing Datalogger Programs Short Cut can also create programs for dataloggers using a variety of interface devices, includin

Seite 149 - 5.1.7 Data Displays

Section 7. Creating and Editing Datalogger Programs 7.2.2.4 Step 4 – Setup Output Tables After selecting the sensors to be measured, you can choose

Seite 150

Section 7. Creating and Editing Datalogger Programs Note that outputs for a sensor don’t have to be added in the same sequence as the measurement.

Seite 151

Section 7. Creating and Editing Datalogger Programs The Advanced Output allows you to store data based on time, the state of a flag, the value of a m

Seite 152

Section 7. Creating and Editing Datalogger Programs 7.2.2.5 Step 5 – Generate the Program in the Format Required by the Datalogger The Finish button

Seite 153

Section 7. Creating and Editing Datalogger Programs The Summary tab displays the information in the DEF file as described above. The Advanced tab (f

Seite 154

Section 7. Creating and Editing Datalogger Programs controls are off when a datalogger powers up so as to make the control decision based on a fresh

Seite 155

Section 7. Creating and Editing Datalogger Programs 7.2.3.6 Integration Some dataloggers have parameters available in their measurement instructions

Seite 156

Section 7. Creating and Editing Datalogger Programs 7.2.5 New Sensor Files Short Cut was designed with future flexibility in mind. Datalogger and s

Seite 157

Preface — What’s New in LoggerNet 4? Connect Screen The Connect Screen has been reorganized with most of the buttons now residing on a toolbar at the

Seite 158

Section 7. Creating and Editing Datalogger Programs 7.3.2 Inserting Instructions An instruction can be easily inserted into the program by highligh

Seite 159

Section 7. Creating and Editing Datalogger Programs Below is an example of the Parameter dialog box for the differential voltage instruction (VoltDif

Seite 160

Section 7. Creating and Editing Datalogger Programs Pressing F9 at any time will also bring up a list of variables. However, when a variable is chos

Seite 161

Section 7. Creating and Editing Datalogger Programs • Insert File: Inserts a library file into the current program overwriting the highlighted text.

Seite 162

Section 7. Creating and Editing Datalogger Programs Undo – Each time the Undo button is clicked it will step back through the last changes made to t

Seite 163

Section 7. Creating and Editing Datalogger Programs Clear Bookmarks – Erases all bookmarks from the program. GoTo – Moves the cursor to a particula

Seite 164 - 5.1.8 Table Monitor

Section 7. Creating and Editing Datalogger Programs This function first checks the program for errors using the pre-compiler, then saves the program

Seite 165

Section 7. Creating and Editing Datalogger Programs programs. A program with the extension of .DLD will be associated with all CRBasic-programmed dat

Seite 166

Section 7. Creating and Editing Datalogger Programs CR9000(X)/CR5000 Datalogger Run Now Options The Run Now options and behavior for the CR9000(X) an

Seite 167

Section 7. Creating and Editing Datalogger Programs Sending the Program To send the file and perform the associated functions you have selected in th

Seite 168

Preface — What’s New in LoggerNet 4? Short Cut Support has been added to Short Cut for the CR9000X datalogger, the ET107 Evapotranspiration Monitorin

Seite 169 - 5.1.10 Terminal Emulator

Section 7. Creating and Editing Datalogger Programs Save as Default Template - Saves the comments and instructions in the active file as a template t

Seite 170 - 5.1.11 Station Status

Section 7. Creating and Editing Datalogger Programs 7.3.3.7 CRBasic Editor Edit Menu This menu item allows you to edit and manipulate the text curre

Seite 171 - 5.1.12 Calibration Wizard

Section 7. Creating and Editing Datalogger Programs The Vertical Spacing tab is used to set up the rules for the CRBasic Editor's Rebuild Inden

Seite 172 - 5.2.1 Development Mode

Section 7. Creating and Editing Datalogger Programs The Syntax Highlighting tab sets up the appearance of different text elements in the program usin

Seite 173 - 5.2.1.1 The RTMC Workspace

Section 7. Creating and Editing Datalogger Programs Background Color - Displays a color selection dialog to set the color of the CRBasic program wind

Seite 174 - 5.2.1.2 Display Components

Section 7. Creating and Editing Datalogger Programs 7.3.3.9.2 Constant Customization The Constant Customization feature allows you to define values

Seite 175

Section 7. Creating and Editing Datalogger Programs The Constant Customization syntax may be best understood by looking at an example. Consider the f

Seite 176

Section 7. Creating and Editing Datalogger Programs The constant SInterval is defined with a default value of 10, a maximum of 60 and a minimum of 5,

Seite 177

Section 7. Creating and Editing Datalogger Programs 7.3.3.10 Available Help Information Pressing the Help button of the Parameter dialog box will br

Seite 178

Section 7. Creating and Editing Datalogger Programs Program The program section defines the action of datalogging. Set scan interval The scan sets

Seite 179

Preface — What’s New in LoggerNet 4? Variable Name Matching – When enabled variable names will be capitalized based on how they are declared in the pr

Seite 180 - 5.2.1.4 Expressions

Section 7. Creating and Editing Datalogger Programs 7.3.4.3 Mathematical Expressions Mathematical expressions can be entered algebraically into prog

Seite 181 - FromNewest(5,Order

Section 7. Creating and Editing Datalogger Programs 7.3.4.5 Line Continuation Line continuation allows an instruction or logical line to span one or

Seite 182

Section 7. Creating and Editing Datalogger Programs 7.3.4.7 Example Program The following program will serve as a programming example in this sectio

Seite 183

Section 7. Creating and Editing Datalogger Programs The data table header may also have a row that lists units for the output values. The units must

Seite 184

Section 7. Creating and Editing Datalogger Programs The output processing instructions included in a data table declaration determine the values outp

Seite 185

Section 7. Creating and Editing Datalogger Programs The Scan instruction determines how frequently the measurements within the scan are made: Scan(In

Seite 186

Section 7. Creating and Editing Datalogger Programs TABLE 7-3. Synonyms for True and False Predefined Constant True (-1) False (0) Synonym High

Seite 187

Section 7. Creating and Editing Datalogger Programs 7.3.4.12 Flags Any variable can be used as a flag as far as logical tests in CRBasic are concern

Seite 188 - MinRunOverTimeWithReset

Section 7. Creating and Editing Datalogger Programs DataTable(Name, TrigVar, Size) DataTable(Temp, TC(1)>100, 5000) Entering the trigger as the ex

Seite 189 - 5.2.2 RTMC Run-Time

Section 7. Creating and Editing Datalogger Programs Tablename.record(1,n) = the record number of the record output n records ago. Tablename.output(1,

Seite 190

Preface — What’s New in LoggerNet 4? In RTMC Run-Time, all alarms on a screen can be acknowledged by right-clicking on the screen and then choosing “A

Seite 191 - 6.1 Status Monitor

Section 7. Creating and Editing Datalogger Programs is also created. For mixed-array dataloggers the precompiler also creates a Final Storage Label

Seite 192

Section 7. Creating and Editing Datalogger Programs For example, the following expression could be used to create a new input location for temperatur

Seite 193 - 6.1.2.1 Selecting Columns

Section 7. Creating and Editing Datalogger Programs The first line of text identifies the type of datalogger program to be written. This is followed

Seite 194

Section 7. Creating and Editing Datalogger Programs − Control – Do any control of external hardware or devices. − Output Data – Check to see if it

Seite 195

Section 7. Creating and Editing Datalogger Programs • *.TXT – Printer output files created by Edlog are saved with a TXT extension. These files can

Seite 196

Section 7. Creating and Editing Datalogger Programs 7.4.2.4 Entering Parameters for the Instructions When an instruction is inserted, the cursor mov

Seite 197

Section 7. Creating and Editing Datalogger Programs 7.4.2.6 Expressions Algebraic expressions can be used in a program to easily perform processing

Seite 198 - 6.1.2.4 Reset Device

Section 7. Creating and Editing Datalogger Programs TABLE 7-5. Operators and Functions Operators * multiply / divide + add – subtract ^ raise t

Seite 199 - 6.1.2.6 Pool Statistics

Section 7. Creating and Editing Datalogger Programs Execution Interval = 10 sec ;this instruction reads the temperature probe ;the output is in degr

Seite 200 - 6.1.2.8 State of Operations

Section 7. Creating and Editing Datalogger Programs Errors That Can Occur With Expressions Some of the error messages that occur when using expressio

Seite 201

Preface — What’s New in LoggerNet 4? Splitr is started when one is already running, another log file, splitrunning.log, will be written. This file sim

Seite 202 - 6.2 LogTool

Section 7. Creating and Editing Datalogger Programs Floating Point Numbers Limited to 5 Digits All fixed numbers are limited to five digits not inclu

Seite 203 - 6.2.2 Using LogTool

Section 7. Creating and Editing Datalogger Programs For Example: This error message is displayed when a program contains any of these expressions: re

Seite 204 - 6.2.3 Saving Logs to File

Section 7. Creating and Editing Datalogger Programs TABLE 7-6. Editor Keystrokes PgUp Page Up PgDn Page Down Up Arrow Move Up One Line Down Arrow

Seite 205 - 6.3 Comm Test

Section 7. Creating and Editing Datalogger Programs 7.4.2.8 Editing Comments, Instructions, and Expressions To edit Comments, Expressions, and Instr

Seite 206 - 6.4 PakBus Graph

Section 7. Creating and Editing Datalogger Programs Programs created with the DOS versions of Edlog earlier than 6.0 were stored with the instruction

Seite 207

Section 7. Creating and Editing Datalogger Programs Open the on-line help system. 7.4.5.2 Renumbering the Instructions When Automatic Renumbering i

Seite 208 - 6.5 Troubleshooter

Section 7. Creating and Editing Datalogger Programs 7.4.7 Entering Input Locations When a parameter requires an Input Location, the cursor automatic

Seite 209 - 6.5.1 Status Information

Section 7. Creating and Editing Datalogger Programs 12: If time is (P92) 1: 0 minutes into interval 2: 60 minute interval 3: 10 S

Seite 210 - 6.5.3 TD-RF Test

Section 7. Creating and Editing Datalogger Programs Editing functions are available from the Input Location Editor’s Edit menu and a hot key: Insert

Seite 211

Section 7. Creating and Editing Datalogger Programs • Instruction 75, Histogram • Instruction 80, Store Area • Instruction 81, Rainflow Histogram

Seite 212

Preface — What’s New in LoggerNet 4? Status Monitor, Task Master, Short Cut, CRBasic Editor, View Pro, Card Convert, TroubleShooter, Network Planner,

Seite 213

Section 7. Creating and Editing Datalogger Programs The user can create a custom label to reflect the meaning of the value that is being stored. Cli

Seite 214

Section 7. Creating and Editing Datalogger Programs If changes are made to measurement or output instructions after custom final storage labels have

Seite 215 - TD-RF QUALITY REPORT

Section 7. Creating and Editing Datalogger Programs 7.4.14 Final Storage Area 2 The ring memory for CR10, CR10X, CR510, and CR23X dataloggers can be

Seite 216 - 6.5.3.3 Advanced Features

Section 7. Creating and Editing Datalogger Programs If you are trying to minimize the size of your DLD file but still want to be able to monitor inpu

Seite 217

Section 7. Creating and Editing Datalogger Programs 7.4.18 PakBus Settings PakBus dataloggers have various settings that allow them to function prop

Seite 218

Section 7. Creating and Editing Datalogger Programs 7.4.18.3 Neighbor Filter This option allows you to list expected neighbors that are available to

Seite 219 - Datalogger Programs

Section 7. Creating and Editing Datalogger Programs The Source File is the CSI or DLD file to be converted. The Program File is the new CR* file tha

Seite 220 - 7.2 Short Cut

Section 7. Creating and Editing Datalogger Programs Comments about the conversion are shown in the Action Log (bottom portion of the window). The Ac

Seite 221

Section 7. Creating and Editing Datalogger Programs 7-80

Seite 222

Section 8. Working with Data Files on the PC After data has been collected from the datalogger, you need a way to analyze that data. LoggerNet prov

Seite 223

License for Use This software is protected by United States copyright law and international copyright treaty provisions. The installation and use of t

Seite 224

Preface — What’s New in LoggerNet 4? xxvi

Seite 225

Section 8. Working with Data Files on the PC View Pro is closed by selecting File | Exit from the menu or pressing the red X in the upper right-hand

Seite 226

Section 8. Working with Data Files on the PC New Histogram. Brings up a Histogram window from which you can view Histogram data values. New XY Plot

Seite 227

Section 8. Working with Data Files on the PC 8.1.3 Opening a File View Pro provides three ways to open a file. The one you use depends on the type

Seite 228

Section 8. Working with Data Files on the PC The information to enter changes depending on the database type as described below: SQL Server Compact

Seite 229

Section 8. Working with Data Files on the PC SQL Server To configure a connection to SQL Server you must select a SQL Server instance. The list of p

Seite 230

Section 8. Working with Data Files on the PC MySQL The MySQL connection is an ODBC connection. You must use the Windows ODBC Data Source Administrat

Seite 231

Section 8. Working with Data Files on the PC 8.1.4.2 Selecting a Table The Select Table dialog box comes up once a database has been selected. Sel

Seite 232

Section 8. Working with Data Files on the PC File The name of the file to be imported. Press the File button to bring up a browser to select the de

Seite 233

Section 8. Working with Data Files on the PC Date and Time Format Codes yy = Year last 2 digits yyyy = Year as 4 digits m = Month number no-leading

Seite 234

Section 8. Working with Data Files on the PC 8.1.6 Data View The initial display for data files in View Pro is as normal text in a grid format. The

Seite 235 - Datalogger

Section 1. System Requirements 1.1 Hardware and Software LoggerNet is a collection of 32-bit programs designed to run on Intel-based computers runn

Seite 236 - 7.2.3 Short Cut Settings

Section 8. Working with Data Files on the PC Array-based data files do not contain timestamps. If an FSL file is associated with the data file, View

Seite 237 - 7.2.3.5 Sensor Support

Section 8. Working with Data Files on the PC 8.1.6.7 Window Arrangement When multiple data files are opened, they are arranged so that the title bar

Seite 238 - 7.2.3.7 Font

Section 8. Working with Data Files on the PC Zoom Feature You can zoom in on a particular area of a graph by holding the left mouse button and draggi

Seite 239 - 7.3 CRBasic Editor

Section 8. Working with Data Files on the PC 8.1.7.1 Line Graph From the Line Graph screen, you can graph data values on the y-axis against their ti

Seite 240

Section 8. Working with Data Files on the PC Creating Multiple Line Graphs To open an additional Line Graph, select “None” from the Selected Graph dr

Seite 241

Section 8. Working with Data Files on the PC 8.1.7.1.5 Line Graph Toolbar The Line Graph toolbar includes the following icons: Statistics. Display

Seite 242

Section 8. Working with Data Files on the PC Lock Scrolling. Locks and unlocks the scroll bar at the bottom of the graph. When unlocked, moving the

Seite 243 - 7.3.3 Toolbar

Section 8. Working with Data Files on the PC When the data panels and graphs are currently synchronized, the button icon will have a check mark in t

Seite 244

Section 8. Working with Data Files on the PC 8.1.7.2.1 Selecting Data to be Viewed From a Histogram Screen When a Histogram screen is first opened w

Seite 245 - 7.3.3.1 Compile

Section 8. Working with Data Files on the PC All histogram records from the same histogram will have the same default name in the list. They can be d

Seite 246

Section 1. System Requirements 1-2

Seite 247

Section 8. Working with Data Files on the PC Show/Hide Gradient. A toggle button that turns on and off the gradient background of the Histogram. It

Seite 248

Section 8. Working with Data Files on the PC 8.1.7.3.1 Selecting Data to be Plotted To select the data value(s) to be plotted, highlight the column

Seite 249 - 7.3.3.4 Templates

Section 8. Working with Data Files on the PC 8.1.7.4 Rainflow Histogram From the Rainflow Histogram screen, you can view rainflow histogram data. T

Seite 250

Section 8. Working with Data Files on the PC 8.1.7.4.1 Selecting Data to be View From a Rainflow Histogram Screen When a Rainflow Histogram screen i

Seite 251

Section 8. Working with Data Files on the PC left side of the Rainflow Histogram screen. A rainflow histogram record can then be displayed by clickin

Seite 252

Section 8. Working with Data Files on the PC Show/Hide Gradient. A toggle button that turns on and off the gradient background of the Rainflow Histo

Seite 253

Section 8. Working with Data Files on the PC 8.1.7.5.1 Selecting Data to be Graphed From an FFT Screen When an FFT screen is opened, a Fast Fourier

Seite 254

Section 8. Working with Data Files on the PC All FFT records from the same FFT will have the same default name in the list. They can be distinguished

Seite 255

Section 8. Working with Data Files on the PC Show Table. Brings the main View Pro window in front of other windows, making the data file(s) visible.

Seite 256

Section 8. Working with Data Files on the PC The records included can be defined by initial and ending time, time span, initial and ending record, or

Seite 257

Section 2. Installation, Operation and Backup Procedures 2.1 CD-ROM Installation Place the installation disk in your computer’s CD-ROM drive. If a

Seite 258 - 7.3.4 CRBasic Programming

Section 8. Working with Data Files on the PC Goto Bookmark If the data panel contains one or more bookmarks, hovering over the Goto Bookmark menu ite

Seite 259

Section 8. Working with Data Files on the PC 8.1.9.2 Printing Text To print numerical data, press the Print button or select File | Print from the

Seite 260 - End If

Section 8. Working with Data Files on the PC In addition to splitting out mixed-array data, Split can filter output data based on time or conditions,

Seite 261 - 7.3.4.5 Line Continuation

Section 8. Working with Data Files on the PC When Edlog compiled Birch.dld, it also created the Final Storage Label file, Birch.fsl that lists the f

Seite 262 - 7.3.4.8 Data Tables

Section 8. Working with Data Files on the PC When you start Split a blank template similar to the one above is shown. This template is used to ente

Seite 263

Section 8. Working with Data Files on the PC In this example we want the hourly data (note the Output Interval at the bottom of the Data File Label

Seite 264

Section 8. Working with Data Files on the PC Note that the cursor in the INPUT FILE(S) screen must be in valid paste area (Copy or Select). If the

Seite 265 - 7.3.4.10 Numerical Entries

Section 8. Working with Data Files on the PC Maximum column heading width is one less than the number entered in the Default Column Width field. Ho

Seite 266

Section 8. Working with Data Files on the PC Close the Run window. If you wish to save this parameter file for future reports, choose FILE | SAVE.

Seite 267 - 7.3.4.13 Parameter Types

Section 8. Working with Data Files on the PC Split’s default output file, a field-separated ASCII format with a *.PRN file extension, can be processe

Seite 268

Section 2. Installation, Operation and Backup Procedures Note that the trial version will install some applications in the C:\Program Files\Campbells

Seite 269 - 7.4 Edlog

Section 8. Working with Data Files on the PC A maximum of eight input files may be processed by Split at one time. Additional input files are added

Seite 270 - 7.4.1.6 Expression Compiler

Section 8. Working with Data Files on the PC Last Count Each time Split runs a parameter file, it keeps track of the number of bytes it read from the

Seite 271

Section 8. Working with Data Files on the PC In the following figure, Split will skip the first 256 bytes of data before it begins processing the dat

Seite 272 - 7.4.2.1 Program Structure

Section 8. Working with Data Files on the PC Stop Offset This number specifies the number of bytes from the beginning of the file that Split should s

Seite 273 - 7.4.2.2 Edlog File Types

Section 8. Working with Data Files on the PC For example, with an input timestamp of “2008-10-09 10:25” and an offset of 3600, the timestamp output b

Seite 274

Section 8. Working with Data Files on the PC Logical “and” and “or” statements can be used when specifying the Start Condition. A logical “and” stat

Seite 275 - 7.4.2.5 Program Comments

Section 8. Working with Data Files on the PC telling Split where to Start reading relative to the PC clock, the Start Conditions do not need to be ch

Seite 276 - 7.4.2.6 Expressions

Section 8. Working with Data Files on the PC 8.2.3.1.4 Stop Condition The Stop Condition specifies when to stop processing data. This feature allow

Seite 277

Section 8. Working with Data Files on the PC Split menu. The same data file will be used as the Input File for each array. • Type in the array ID i

Seite 278

Section 8. Working with Data Files on the PC To process these files using the C option, the parameter file would be set up as follows (assuming the n

Seite 279

Section 2. Installation, Operation and Backup Procedures 2.3.1 LoggerNet Directory Structure and File Descriptions 2.3.1.1 Program Directory As des

Seite 280

Section 8. Working with Data Files on the PC A typical application for the Trigger on Stop Condition is to reduce days of hourly data into daily summ

Seite 281

Section 8. Working with Data Files on the PC The Copy Condition is used almost exclusively for mixed-array dataloggers, except when time-syncing two

Seite 282

Section 8. Working with Data Files on the PC 8.2.3.1.7 Ranges Element numbers may be entered individually (e.g., 2,3,4,5,6,7), or, in groups (e.g.,

Seite 283 - 7.4.3 Library Files

Section 8. Working with Data Files on the PC In this instance, out of range data refers to data outside of the specified output range. It is not to

Seite 284 - 7.4.5 Display Options

Section 8. Working with Data Files on the PC 8.2.3.1.10 Mathematical Functions, Details, and Examples TABLE 8-6. Split Operators and Math Function

Seite 285 - 7.4.6 Input Locations

Section 8. Working with Data Files on the PC The following array of ASCII data will be used for all Mathematical function examples. 0105 0176 1200

Seite 286 - 7.4.8 Repetitions

Section 8. Working with Data Files on the PC SpaMax(x..y) returns the maximum value of elements x through y. Examples: SpaMax(1..7) = 1200 SpaMa

Seite 287 - 7.4.9 Input Location Editor

Section 8. Working with Data Files on the PC Time Series functions are used to perform vertical processing on selected elements, such as calculating

Seite 288

Section 8. Working with Data Files on the PC Semicolons are used in Time Series functions to separate the elements or expressions from the count whic

Seite 289 - 7.4.11 Final Storage Labels

Section 8. Working with Data Files on the PC Count(x;n) returns the number of data points (non blanks) in element x over a full data set or every nt

Seite 290

Section 2. Installation, Operation and Backup Procedures By default, the files that you create in each of the applications will be stored in their r

Seite 291 - 7.4.13 Program Security

Section 8. Working with Data Files on the PC 1.1182 (Sd temp for 8 hours) 4.965 (Sd temp for 8 hours) Smpl(x;n) returns a sample of

Seite 292 - 7.4.14 Final Storage Area 2

Section 8. Working with Data Files on the PC 8.2.3.1.12 Special Functions, Details, and Examples TABLE 8-8. Split SPECIAL FUNCTIONS Crlf = Insert

Seite 293

Section 8. Working with Data Files on the PC The Crlf is placed after the maximum temperature 67.33 so that the maximum RH is on the next line. A c

Seite 294 - 7.4.18 PakBus Settings

Section 8. Working with Data Files on the PC 23 38.8 17.12 24 37.13 11.86 Smpl (Line;8), Smpl (4;8), Smpl (5;8) 1 23.98 6.588

Seite 295 - 7.5 Transformer Utility

Section 8. Working with Data Files on the PC When using the Date function for a table-based datalogger (e.g., a time stamp in the format “2002-02-0

Seite 296

Section 8. Working with Data Files on the PC edate(“mm/dd/yy, hh:nn”;1;1;1;1) 02/25/02, 04:10 edate(“yyyy”, “dayofyear”, “hhnn”;1;1;1;1) 2002, 56,

Seite 297 - 7.5.2 Controls

Section 8. Working with Data Files on the PC 8.2.3.1.13 Split Functions Example The following is a parameter file that operates on the Mt. Logan da

Seite 298

Section 8. Working with Data Files on the PC The following screen shows the output file setup including the column headings and the units. This .PAR

Seite 299 - 8.1 View Pro

Section 8. Working with Data Files on the PC Wind Chill Report from Mt. Logan Temp deg C Wind Speed m/s H Wind Chill deg C Wind Chill deg F 14.75

Seite 300 - 8.1.2 The Toolbar

Section 8. Working with Data Files on the PC • A single expression can operate on a set of elements. For example, the expression (3..6,8)/2.0 is th

Seite 301

Section 2. Installation, Operation and Backup Procedures files and help files for all dataloggers supported by the CRBasic Editor. The definition fi

Seite 302 - 8.1.3 Opening a File

Section 8. Working with Data Files on the PC Typically, the starting time specified must actually be found in the input file before the Start Conditi

Seite 303

Section 8. Working with Data Files on the PC 8.2.3.1.15.1 Time Synchronization and the Copy Condition To use the time synchronize function, time ele

Seite 304

Section 8. Working with Data Files on the PC 8.2.3.2 Output Files To create an Output File, click the OUTPUT FILE tab. The file is created on the d

Seite 305

Section 8. Working with Data Files on the PC 8.2.3.2.1 Description of Output Option Commands File Format There are five File Format options to cho

Seite 306 - 8.1.5 Importing a CSV File

Section 8. Working with Data Files on the PC Screen Display The Screen Display field controls writing the processed data to the screen. To write to

Seite 307

Section 8. Working with Data Files on the PC It allows the following settings to be modified: Replace bad data with – The text in the field, to the r

Seite 308

Section 8. Working with Data Files on the PC The Copy Condition determines the interval of your data. Therefore, to output data that occurs every 24

Seite 309 - 8.1.6 Data View

Section 8. Working with Data Files on the PC summary of the left over values and the Time Series Heading from the report. No Date Advance – When proc

Seite 310

Section 8. Working with Data Files on the PC Heading and Column Headings from being printed at the bottom of the report. The “left over” summary dat

Seite 311 - 8.1.7 Graphs

Section 8. Working with Data Files on the PC 8.2.5 Editing Commands Split supports the Windows Cut, Copy, and Paste commands. Text from any field i

Seite 312

Section 2. Installation, Operation and Backup Procedures The backup file is named LoggerNet.bkp and is stored in the C:\CampbellSci\LoggerNet directo

Seite 313 - 8.1.7.1 Line Graph

Section 8. Working with Data Files on the PC 8.2.6.1.3 Running Multiple Copies of Splitr (/M Switch) Multiple copies of Splitr can be run at one tim

Seite 314

Section 8. Working with Data Files on the PC If a parameter is to be left as it is in the parameter file, then space comma space ( , ) may be entered

Seite 315

Section 8. Working with Data Files on the PC /[text] Sets the text that will be used in the place of bad data. This is the same as the text string u

Seite 316

Section 8. Working with Data Files on the PC /H Removes the dashed lines from the heading of the RPT file. This is the same as choosing the No Dashe

Seite 317 - 8.1.7.2 Histogram

Section 8. Working with Data Files on the PC /M Changes the value for midnight to 2400 instead of 0000. This is the same as selecting Midnight is 24

Seite 318

Section 8. Working with Data Files on the PC 8.3.1 Input/Output File Settings The file settings are used to specify the directory where the binary d

Seite 319

Section 8. Working with Data Files on the PC 8.3.2.1 File Format The File Format is used to specify the format in which the data file should be save

Seite 320 - 8.1.7.3 XY Plot

Section 8. Working with Data Files on the PC _1 at the end of the root file name (e.g., TOA5_Mytable_1.dat). The number is incremented by one with ea

Seite 321

Section 8. Working with Data Files on the PC The Create New Filenames option is disabled when the Use Filemarks, Use Removemarks, or Use Time option

Seite 322 - 8.1.7.4 Rainflow Histogram

Section 8. Working with Data Files on the PC In some instances, data on a card can become corrupted. Corruption can occur if the card is subjected to

Seite 323

Section 2. Installation, Operation and Backup Procedures Automatic Backup Configured in Task Master 2.3.2.4 Restoring the Network from a Backup Fil

Seite 324

Section 8. Working with Data Files on the PC When running CardConvert from a command line, you can designate the CCF file using the command line opti

Seite 325 - 8.1.7.5 FFT

Section 9. Automating Tasks with Task Master The Task Master is an application that is used to set up a Task that can be run on a defined schedule o

Seite 326

Section 9. Automating Tasks with Task Master 9.1.1 Setup Tab 9.1.1.1 Adding Tasks To add a task that will run based on a data collection event for

Seite 327

Section 9. Automating Tasks with Task Master Tasks can be renamed by selecting the task and then clicking again on the task name. The name will turn

Seite 328 - 8.1.8 Right-click-Menus

Section 9. Automating Tasks with Task Master • After Any Scheduled Call – After a scheduled data collection attempt, regardless of whether or not th

Seite 329

Section 9. Automating Tasks with Task Master the file name ahead of time. Therefore, the %F option can be used to insert the file name in the command

Seite 330 - 8.1.9 Printing Options

Section 9. Automating Tasks with Task Master 9.1.1.3 Scheduled Event Tasks An alternative to event driven tasks, scheduled tasks are repeated at a s

Seite 331 - 8.2 Split

Section 9. Automating Tasks with Task Master 9.1.1.3.2 Calendar Set the Hours of the Day, Minutes of the Hour, Days of Month, Days of Week, and Mon

Seite 332 - 8.2.2 Getting Started

Section 9. Automating Tasks with Task Master Month to 1, 2, 3, 4, 5, 6, 7, the Days of the Week to 2-Monday, and leave the other settings blank. To e

Seite 333

Section 9. Automating Tasks with Task Master 9.1.1.4 Define What the Task Does The “What Task Does” tab describes the action that will be taken when

Seite 334

Limited Warranty The following warranties are in effect for ninety (90) days from the date of shipment of the original purchase. These warranties are

Seite 335

Section 2. Installation, Operation and Backup Procedures If computer system power is lost while the LoggerNet server is writing data to the active fi

Seite 336

Section 9. Automating Tasks with Task Master Always enter the full path when specifying the file to execute. Otherwise, the file may not be found or

Seite 337

Section 9. Automating Tasks with Task Master Any data file associated with the designated station will be transferred, whenever that file is closed.

Seite 338 - 8.2.3.1 Input Files

Section 9. Automating Tasks with Task Master Example #2: The following configuration will run LNBackup.exe to perform an automated backup. The –Appe

Seite 339

Section 9. Automating Tasks with Task Master 9-13

Seite 340 - become accessible. Enter

Section 9. Automating Tasks with Task Master Example #4: The following configuration will set up a task to perform a clock check on the datalogger th

Seite 341

Section 9. Automating Tasks with Task Master Task Name – The name that was given to the task when it was set up. Action – Indicates whether the tas

Seite 342

Section 9. Automating Tasks with Task Master • Communications Disabled • Bad Table Definitions • Task Disabled • Datalogger is Locked • File

Seite 343

Section 10. Utilities Installed with LoggerNet Along with LoggerNet’s server, clients and program editors, we also install several utilities. These

Seite 344

Section 10. Utilities Installed with LoggerNet 10.1.2 Main DevConfig Screen The DevConfig window is divided into two main sections: the device sele

Seite 345

Section 10. Utilities Installed with LoggerNet Two common operations are sending a new operating system and communicating with a device in terminal e

Seite 346

Section 2. Installation, Operation and Backup Procedures Note that when running LoggerNet as a service, tasks being run by the Task Master cannot int

Seite 347

Section 10. Utilities Installed with LoggerNet When the operating system has been sent to the device, a message dialog will appear similar to the on

Seite 348

Section 10. Utilities Installed with LoggerNet 10.1.4 Terminal Tab The Terminal tab will be available when the application is connected to any devic

Seite 349

Section 10. Utilities Installed with LoggerNet Clicking Connect puts DevConfig into Terminal emulation mode on the Serial Port and at the Baud Rate

Seite 350

Section 10. Utilities Installed with LoggerNet 10.2 CoraScript 10.2.1 CoraScript Fundamentals CoraScript is a command line interpreter that reads i

Seite 351

Section 10. Utilities Installed with LoggerNet • Command parameters are often set using a combination of the parameter name and the value in this fo

Seite 352

Section 10. Utilities Installed with LoggerNet You may want to consider using LoggerNet’s Scheduled Backup/Manual Backup/Restore Network options avai

Seite 353

Section 10. Utilities Installed with LoggerNet 10.2.2.5 Scripting CoraScript Commands To automate network processes, scripts can be created with oth

Seite 354

Section 10. Utilities Installed with LoggerNet The following items are available from this main screen: RWIS Stations – Lists all RWIS stations that

Seite 355

Section 10. Utilities Installed with LoggerNet in the Stations List once the add is complete and the settings panels will reflect the default setting

Seite 356

Section 10. Utilities Installed with LoggerNet SNMP Private Community – Enter the “community” string that will be sent with SNMP SET requests. Like

Seite 357

Section 2. Installation, Operation and Backup Procedures Giving the LoggerNet user write access This is the process for giving the LoggerNet user wri

Seite 358

Section 10. Utilities Installed with LoggerNet elapsed since the last attempt, LoggerNet will immediately try to perform a poll. In some cases, this

Seite 359

Section 10. Utilities Installed with LoggerNet File Format – Specify the format for the selected file. Options include the following: CSV – Data i

Seite 360

Section 10. Utilities Installed with LoggerNet Controls on this panel include the following: Collect Snapshots on Schedule – Select this check box to

Seite 361

Section 10. Utilities Installed with LoggerNet Controls on this panel include the following: Automated Clock Check – This check box is used to turn t

Seite 362 - Examples:

Section 10. Utilities Installed with LoggerNet 10.3.3.5 Data Tab The fifth tab can be used to view the values associated with the most recently coll

Seite 363

Section 10. Utilities Installed with LoggerNet station’s version number. Variables that can have multiple instances are represented as subscripted a

Seite 364

Section 10. Utilities Installed with LoggerNet To: • TOA5 • TOACI1 • TOB1 • CSIXML • CSV File Format Convert cannot produce TOB2 or TOB3 files,

Seite 365

Section 10. Utilities Installed with LoggerNet File Check Write File to cause an output file to be created. The file will be created in the same dir

Seite 366

Section 10. Utilities Installed with LoggerNet Discontinuity – A new file is created when missing records are encountered (see Check section above).

Seite 367

Section 11. Utilities Installed with LoggerNet Admin and LoggerNet Remote The LoggerNet Admin and LoggerNet Remote packages include several additiona

Seite 368

Section 2. Installation, Operation and Backup Procedures (which will already be “behind” the PC’s local firewall), the server is capable of distribut

Seite 369

Section 11. Utilities Installed with LoggerNet Admin and LoggerNet Remote Enter the IP address or alias for the LoggerNet server (e.g., LocalHost), l

Seite 370

Section 11. Utilities Installed with LoggerNet Admin and LoggerNet Remote Confirm Password Enter the password for the account a second time. Securi

Seite 371

Section 11. Utilities Installed with LoggerNet Admin and LoggerNet Remote TABLE 11-1. Security Manager Access Table Read Station Network Full Onl

Seite 372 - 8.2.3.2 Output Files

Section 11. Utilities Installed with LoggerNet Admin and LoggerNet Remote Deleting an Account To delete an account, highlight it and press the Delete

Seite 373

Section 11. Utilities Installed with LoggerNet Admin and LoggerNet Remote hole. If the data has been overwritten by the datalogger, then it is an unc

Seite 374

Section 11. Utilities Installed with LoggerNet Admin and LoggerNet Remote detected – This state, printed with black text, indicates that the hole h

Seite 375

Section 11. Utilities Installed with LoggerNet Admin and LoggerNet Remote 11.3 Data Filer Data Filer is a LoggerNet application that is used to retr

Seite 376

Section 11. Utilities Installed with LoggerNet Admin and LoggerNet Remote 11.3.2.1.1 Setting Up the Data Filer Once connection to the LoggerNet serv

Seite 377

Section 11. Utilities Installed with LoggerNet Admin and LoggerNet Remote File Format This option is used to determine the format in which the data f

Seite 378 - 8.2.4 Help Option

Section 11. Utilities Installed with LoggerNet Admin and LoggerNet Remote Starting Date/Time and Ending Date/Time The Starting Date/Time and Ending D

Seite 379 - 8.2.5 Editing Commands

Section 2. Installation, Operation and Backup Procedures 2-12

Seite 380

Section 11. Utilities Installed with LoggerNet Admin and LoggerNet Remote 11.3.5 Record Number Anomalies Under certain circumstances it may appear t

Seite 381

Section 11. Utilities Installed with LoggerNet Admin and LoggerNet Remote Once the data tables to be exported are specified, the user selects an outp

Seite 382

Section 11. Utilities Installed with LoggerNet Admin and LoggerNet Remote where “directory” is a keyword indicating that the next parameter “pathname

Seite 383

Section 11. Utilities Installed with LoggerNet Admin and LoggerNet Remote the unsent records remain in the LoggerNet server’s data cache. The Data E

Seite 384 - 8.3 CardConvert

Section 11. Utilities Installed with LoggerNet Admin and LoggerNet Remote of the datalogger name, table name and the record number of the received re

Seite 385

Section 11. Utilities Installed with LoggerNet Admin and LoggerNet Remote Session Openexit: Close Session ( )Rec RdySession Failed/ReportReg OK/Repo

Seite 386 - 8.3.2.2 File Processing

Section 11. Utilities Installed with LoggerNet Admin and LoggerNet Remote report a broken socket and so the watchdog is necessary for reliability. Re

Seite 387 - 8.3.2.3 File Naming

Section 11. Utilities Installed with LoggerNet Admin and LoggerNet Remote well being of that record. The server moves on to the next record. Stop N

Seite 388 - 8.3.3 Converting the File

Section 11. Utilities Installed with LoggerNet Admin and LoggerNet Remote 11.4.5 RTMS Format Description The EBNF description of RTMS syntax is as f

Seite 389

Section 11. Utilities Installed with LoggerNet Admin and LoggerNet Remote 11.4.6 Standard Format Description The following is an EBNF syntax of a ne

Seite 390

Section 3. Introduction 3.1 What is LoggerNet? LoggerNet is a software application that enables users to set up, configure, and retrieve data from

Seite 391 - 9.1 Task Master

Section 11. Utilities Installed with LoggerNet Admin and LoggerNet Remote 11-22

Seite 392 - 9.1.1 Setup Tab

Section 12. Optional Client Applications Available for LoggerNet Several client applications are available that are compatible with LoggerNet. Many

Seite 393 - 9.1.1.2 Logger Event Tasks

Section 12. Optional Client Applications Available for LoggerNet 12.3 RTMC Run-Time RTMC Run-Time is an application that allows you to remotely run

Seite 394

Section 12. Optional Client Applications Available for LoggerNet 12.7 CSIOPC Server (PC-OPC) The CSIOPC Server is a LoggerNet client that makes OPC

Seite 395

Section 12. Optional Client Applications Available for LoggerNet 12-4

Seite 396

Section 13. Implementing Advanced Communications Links This section describes the configuration and operation of a variety of communications links.

Seite 397

Section 13. Implementing Advanced Communications Links 13.1.2 Operational Considerations 13.1.2.1 Scheduled Data Collection The intervals for sched

Seite 398

Section 13. Implementing Advanced Communications Links 13.1.3.1 Hardware Setup The RF modem in the RF Base has to be configured to work in Synchrono

Seite 399

Section 13. Implementing Advanced Communications Links To begin, add a Serial Port to the device map if one does not exist. Add a Phone Modem to th

Seite 400

Section 13. Implementing Advanced Communications Links 13.2.2.5 Grounding Depending on the configuration and distance of the MD9 network, be sure to

Seite 401

Section 3. Introduction 3.2 Overview of Major LoggerNet Functions and Associated Software Applications 3.2.1 The Heart of it All – LoggerNet Toolba

Seite 402

Section 13. Implementing Advanced Communications Links 13.3.3 Special Considerations To implement TCP/IP to RF communications, a serial server has t

Seite 403

Section 13. Implementing Advanced Communications Links Subnet Mask – This setting is used to limit the search applicability area for IP addresses. I

Seite 404 - 9.1.2 Status Tab

Section 13. Implementing Advanced Communications Links 13-8

Seite 405

Section 14. Troubleshooting Guide This section is provided as an aid to solving some of the common problems that might be encountered using the Logge

Seite 406 - 9.1.4 Task Master Logs

Section 14. Troubleshooting Guide Problem: Message indicating Server Connection Lost. Remedy : This message indicates that the main communications

Seite 407 - LoggerNet

Section 14. Troubleshooting Guide TABLE 14-1. Socket Error Messages Socket Error Number Message Meaning User Response to Message 10013 Permissi

Seite 408

Section 14. Troubleshooting Guide 14.2.3 Data Collection Issues Problem: Scheduled data collection is enabled but no data is being saved in the data

Seite 409

Section 14. Troubleshooting Guide 14.5 Terminal Emulator to Test Communications Terminal Emulator is a utility to test communications with the devic

Seite 410

Section 14. Troubleshooting Guide Dataloggers The example above shows a terminal emulation session with a datalogger. Once you have selected the dat

Seite 411 - 10.1.4 Terminal Tab

Section 14. Troubleshooting Guide assume you have a Hayes-compatible modem and an array-based datalogger on a phone link with the phone number “752-7

Seite 412 - 10.1.6 Off-line Mode

Section 3. Introduction By default, the LoggerNet menus are not shown on the toolbar. Press the arrow button in the upper right corner to view the Lo

Seite 413 - 10.2 CoraScript

Section 14. Troubleshooting Guide too poor to support communications. A long series of nonsense characters usually indicates electrical noise in the

Seite 414

Section 14. Troubleshooting Guide sections following illustrate things to look for and tests to perform to troubleshoot RF operations. 14.6.1 Checki

Seite 415 - 10.2.2.4 Hole Management

Section 14. Troubleshooting Guide If you are using a data radio that does not have a transmit button built in, you can easily build a push to transmi

Seite 416 - 10.3 RWIS Administrator

Section 14. Troubleshooting Guide If the VSWR is below 1.5:1, then power transmission is good. However, be sure the antenna is oriented properly. Wh

Seite 417

Section 14. Troubleshooting Guide between –95 and –115 dBm which is below the power limit for good data transmission. Similarly, if a 10 dBm attenuat

Seite 418

Section 14. Troubleshooting Guide will not be picked up. If squelch is not broken, then either the signal power is less than –115 dBm, or something

Seite 419 - 10.3.3.2 Schedule Settings

Section 14. Troubleshooting Guide To start Data Table Monitor open Windows Explorer and got to the Program Files\CampbellSci\LoggerNet directory. Do

Seite 420

Section 14. Troubleshooting Guide Setup Screen, no data will be coming into the data cache. Data Table Monitor can only display and output data from

Seite 421 - 10.3.3.3 Snapshots Settings

Section 14. Troubleshooting Guide • At Offset from Newest: This option allows you to specify how many records back from the current write index to g

Seite 422 - 10.3.3.4 Clock Settings

Section 14. Troubleshooting Guide 14.8 Troubleshooting PakBus Communications For additional information on PakBus communication, refer to our PakBus

Seite 423

Section 3. Introduction an application up in the Favorites column, select the application and press the up arrow until the application is in the desi

Seite 424 - 10.3.4 Deleting a Station

Section 14. Troubleshooting Guide include the remote datalogger’s address. Whether you set up a beacon or Neighbor Filter make sure the port so conf

Seite 425 - 10.4 File Format Convert

Section 14. Troubleshooting Guide Remedy: Change one of the duplicate PakBus Addresses. Make all addresses unique throughout the network. Problem: I

Seite 426 - 10.4.2 Options

Section 14. Troubleshooting Guide 14-20

Seite 427

Appendix A. Glossary of Terms A Advise – See Data Advise ASCII File – A computer file containing letters, numbers, and other characters using the AS

Seite 428 - 10.5 Toa_to_tob1

Appendix A. Glossary of Terms Cancel – Choosing Cancel from a dialog box will typically ignore any changes made and close the box. Carrier – An elect

Seite 429 - 11.1 Security Manager

Appendix A. Glossary of Terms D Data Advise (Datalogger) – A mutual agreement between the communication server and the datalogger about which tables

Seite 430 - Adding an Account

Appendix A. Glossary of Terms E Edlog – Campbell Scientific’s software application used to create new or edit existing datalogger programs. Edlog su

Seite 431

Appendix A. Glossary of Terms G Ground Connection – Most sensors require one or more ground connections in addition to excitation or signal inputs.

Seite 432

Appendix A. Glossary of Terms Intermediate Storage – Datalogger memory used to temporarily store values (such as a running total and number of sample

Seite 433 - 11.2 Hole Monitor

Appendix A. Glossary of Terms Modem – From “modulator-demodulator”; a device used to transmit and receive digital data over normally analog communica

Seite 434

Section 3. Introduction Currently, there are three command line arguments: /WorkDir Sets the working directory to something other than the default.

Seite 435 - 11.2.2 Message Log

Appendix A. Glossary of Terms P Packet – a unit of information sent between two BMP or PakBus devices that are communicating. Each packet can contai

Seite 436 - 11.3 Data Filer

Appendix A. Glossary of Terms PROM – Programmable Read-Only Memory ─ integrated circuit chips that are used to store the Operating System (OS) in the

Seite 437 - 11.3.2.2 Collection Options

Appendix A. Glossary of Terms RTMS – Real-Time Monitoring Software. A software application designed by Campbell Scientific for fast real-time data a

Seite 438

Appendix A. Glossary of Terms Station Number – The LoggerNet server assigns and uses station numbers for routing packets to the dataloggers. These n

Seite 439 - 11.3.3 The Collected Data

Appendix A. Glossary of Terms V Variable Name – Edlog uses variable names in expressions. Variables are another name for input location labels. For

Seite 440 - 11.4 Data Export

Appendix B. Campbell Scientific File Formats Campbell Scientific, Inc. uses different formats for data in datalogger memory, external PC cards, data

Seite 441

Appendix B. Campbell Scientific File Formats B.1.2 ASCII Printable Files in ASCII Printable format have the following features: • Data are printed

Seite 442 - 11.4.2 Theory of Operation

Appendix B. Campbell Scientific File Formats B.1.3.1 Field Name Suffixes Each field name will have a suffix corresponding to the output instruction

Seite 443

Appendix B. Campbell Scientific File Formats B.1.4 TOA5 TOA5 is a text-based file format similar to TOACI1 but with additional information in the he

Seite 444

Appendix B. Campbell Scientific File Formats An example of a TOB1 ASCII header: "TOB1","STATION","CR9000","1000&qu

Seite 445

Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links to spec

Seite 446

Section 3. Introduction 3.2.2 LoggerNet Admin/LoggerNet Remote LoggerNet Admin and LoggerNet Remote add functionality to aid in the management of ne

Seite 447

Appendix B. Campbell Scientific File Formats The timestamp and record number for each record are an optional output in a TOB1 file. If these element

Seite 448

Appendix B. Campbell Scientific File Formats attributes. The document is expected to have a single root element which can contain any number of sub-e

Seite 449

Appendix B. Campbell Scientific File Formats In addition to these pre-defined entities, arbitrary unicode characters can be represented by using the

Seite 450

Appendix B. Campbell Scientific File Formats <xsd:element name="model" type="xsd:string" m

Seite 451 - Available for LoggerNet

Appendix B. Campbell Scientific File Formats use="optional" type="xsd:string"/> <xsd:attribute

Seite 452 - 12.6 Baler

Appendix B. Campbell Scientific File Formats B.1.7.3.1.1 The environment Element This element contains sub-elements that provide information about t

Seite 453 - 12.7 CSIOPC Server (PC-OPC)

Appendix B. Campbell Scientific File Formats xsd:short 16 bit signed integer xsd:unsignedShort 16 bit unsigned integer xsd:byte 8 bit signed integ

Seite 454

Appendix B. Campbell Scientific File Formats <head> <environment> <station-name>logan-nw</station-name> <

Seite 455 - Communications Links

Appendix B. Campbell Scientific File Formats <v6>2006-08-16T06:13:46</v6> <v7>52.5</v7> <v8>2006-08-1

Seite 456 - 13.1.2.4 Max Time Online

Appendix B. Campbell Scientific File Formats B.1.8.2 File Syntax CSIJSON contains two subordinate objects: “head” and “data”. The head object contai

Seite 457 - 13.2 Phone to MD9

Section 3. Introduction automatically specifies many individual device settings such as PakBus address, neighbor lists, verify intervals, network par

Seite 458 - 13.2.2.4 Max Time Online

Appendix B. Campbell Scientific File Formats B.1.8.2.1.3 head.environment Object The environment object contains information about the datalogger a

Seite 459 - 13.3 TCP/IP to RF

Appendix B. Campbell Scientific File Formats B.1.8.2.1.4 head.fields Array The fields object is an array of field descriptions for the data contain

Seite 460 - RF Network Base

Appendix B. Campbell Scientific File Formats B.1.8.2.2 The data Array The data array is an array of record objects. Each record object will contain

Seite 461

Appendix B. Campbell Scientific File Formats 69.62625, "2010-01-19T07:53:40", 73.69058, 78.82542, "2010-01-19T17:41:05

Seite 462

Appendix B. Campbell Scientific File Formats The TOB2 or TOB3 binary file format has the following structure with each header line terminated with a

Seite 463 - 14.1 What’s Changed?

Appendix B. Campbell Scientific File Formats Header line five describes the processing performed in the datalogger to produce the value for each fiel

Seite 464 - 14.2.2 Socket Errors

Appendix B. Campbell Scientific File Formats B.4 Converting Binary File Formats Campbell Scientific dataloggers not only use the previously mentione

Seite 465

Appendix B. Campbell Scientific File Formats B.4.5 TOB32.EXE The TOB32.EXE command line utility is installed by default in the LoggerNet program dir

Seite 466

Appendix B. Campbell Scientific File Formats Only without the tabs and carriage return in the middle. One with strings might look like this. PC1,Stat

Seite 467

Appendix C. Table-Based Dataloggers This section describes some of the characteristics and features of the CR10X-TD family and CRx000 family of tabl

Seite 468

Section 3. Introduction Troubleshooter is used to identify possible problems disrupting communications or data collection. You can narrow the displa

Seite 469

Appendix C. Table-Based Dataloggers Event driven tables should have a fixed size rather than allowing them to be allocated automatically. Event driv

Seite 470

Appendix C. Table-Based Dataloggers will calculate the amount of memory for the table based on the execution interval. The CR200 Series dataloggers h

Seite 471

Appendix C. Table-Based Dataloggers 6. Check the Options | DLD File Labels setting to ensure the “Include first ___ Input location labels” field is

Seite 472

Appendix C. Table-Based Dataloggers • Instruction 96, Serial Output – Instruction 96 is used to send data in the active Final Storage area to a stor

Seite 473

Appendix C. Table-Based Dataloggers Example: A CR10X-TD is to be used to monitor three thermocouples. Each hour a temperature for each of the three

Seite 474 - Programmable

Appendix C. Table-Based Dataloggers • Status Table – The Status table contains information on the datalogger. Data is written to the table with eac

Seite 475

Appendix C. Table-Based Dataloggers TABLE C-1. Example of Status Table Entries (CR10T) Battery Current value of the battery voltage. This measureme

Seite 476

Appendix C. Table-Based Dataloggers TABLE C-1. Example of Status Table Entries (CR10T) SkippedSlowScan The number of scans that have been skipped in

Seite 477

Appendix C. Table-Based Dataloggers TABLE C-1. Example of Status Table Entries (CR10T) CardStatus Contains a string with the most recent card status

Seite 478

Appendix D. Software Organization D.1 LoggerNet/Client Architecture The LoggerNet communication server provides the interface to all of the datalog

Seite 479

Section 3. Introduction For straightforward “measurement/control/data storage” datalogger programs, the Short Cut program generator is an excellent c

Seite 480

Appendix D. Software Organization the last poll. The tables to be collected are specified by the user in the Setup Screen. As each record is written

Seite 481

Appendix D. Software Organization D.3 Directory Organization The default installation of the LoggerNet software creates folders and installs softwa

Seite 482

Appendix D. Software Organization application (such as the *.SCW program file for Short Cut for Windows). The client applications are each given the

Seite 483

Appendix E. Log Files E.1 Event Logging As LoggerNet performs its work, it will create records of various kinds of events. The logs can be very us

Seite 484

Appendix E. Log Files E.1.2 Enabling Log Files Use LogTool (Options |Log File Settings) to enable logging of events to files. If enabled, the serve

Seite 485

Appendix E. Log Files E.1.3.2 Transaction Log Format Each record in the transaction log includes at least two fields in addition to the timestamp an

Seite 486

Appendix E. Log Files TABLE E-1. Transaction Log Messages Code Message Text Message Parameters Message Meaning User Response to Message 8 Securi

Seite 487

Appendix E. Log Files TABLE E-1. Transaction Log Messages Code Message Text Message Parameters Message Meaning User Response to Message 15 Start

Seite 488

Appendix E. Log Files TABLE E-1. Transaction Log Messages Code Message Text Message Parameters Message Meaning User Response to Message 24 Hole

Seite 489

Appendix E. Log Files TABLE E-1. Transaction Log Messages Code Message Text Message Parameters Message Meaning User Response to Message 36 Logg

Seite 490

Section 3. Introduction histogram, or FFT as appropriate for the data type. You can also print graphs or save them to disk in a variety of formats.

Seite 491

Appendix E. Log Files TABLE E-1. Transaction Log Messages Code Message Text Message Parameters Message Meaning User Response to Message 44 Term

Seite 492

Appendix E. Log Files TABLE E-1. Transaction Log Messages Code Message Text Message Parameters Message Meaning User Response to Message 54 Prog

Seite 493

Appendix E. Log Files TABLE E-1. Transaction Log Messages Code Message Text Message Parameters Message Meaning User Response to Message 62 Prima

Seite 494

Appendix E. Log Files TABLE E-1. Transaction Log Messages Code Message Text Message Parameters Message Meaning User Response to Message Frequent

Seite 495 - Formats

Appendix E. Log Files TABLE E-1. Transaction Log Messages Code Message Text Message Parameters Message Meaning User Response to Message 75 Logg

Seite 496 - B.1.3 TOACI1

Appendix E. Log Files TABLE E-1. Transaction Log Messages Code Message Text Message Parameters Message Meaning User Response to Message 85 Data

Seite 497 - B.1.3.1 Field Name Suffixes

Appendix E. Log Files TABLE E-1. Transaction Log Messages Code Message Text Message Parameters Message Meaning User Response to Message 93 Coll

Seite 498 - B.1.5 TOB1

Appendix E. Log Files TABLE E-1. Transaction Log Messages Code Message Text Message Parameters Message Meaning User Response to Message 102 Coll

Seite 499

Appendix E. Log Files TABLE E-1. Transaction Log Messages Code Message Text Message Parameters Message Meaning User Response to Message 105 BMP1

Seite 500 - B.1.7 CSIXML

Appendix E. Log Files TABLE E-1. Transaction Log Messages Code Message Text Message Parameters Message Meaning User Response to Message 108 Tabl

Seite 501

Section 3. Introduction data collection must occur in LoggerNet (either by a scheduled or manual data collection), for the data to be available to th

Seite 502 - B.1.7.2 File Syntax

Appendix E. Log Files Transaction Log Example "2009-04-15 16:41:05.367","CR1000","11","Clock check started" &

Seite 503

Appendix E. Log Files Communications Status Log Example "2009-04-15 16:41:05.367","IPPort","S","Device dialed"

Seite 504 - B.1.7.3 The csixml Element

Appendix E. Log Files TABLE E-2. Communication Status Log Messages Message Text Message Meaning User Response to Message PakBus framing error Logg

Seite 505

Appendix E. Log Files E.1.3.4 Object State Log Format The object state log includes two fields in addition to the timestamp and device name: Object

Seite 506 - B.1.7.4 File Example

Appendix E. Log Files E.2 CQR Log (RF Link) The CQR log contains information about the quality of communication each time an RFBase is dialed. (Note

Seite 507

Appendix F. Calibration and Zeroing F.1 Calibration Essentials F.1.1 Definition of Calibration Calibration, in general, refers to actions taken on

Seite 508 - B.1.8 CSIJSON

Appendix F. Calibration and Zeroing F.2 Writing Calibration Programs with the CRBasic Editor F.2.1 The FieldCal Instruction If you wish to make mea

Seite 509 - B.1.8.2 File Syntax

Appendix F. Calibration and Zeroing program start or under other conditions, use the LoadFieldCal instruction. To store calibration values to a data

Seite 510

Appendix F. Calibration and Zeroing F.3.2 Offset Calibration Offset Calibration is the act of placing a sensor into a state where the output conditi

Seite 511

Appendix F. Calibration and Zeroing those two conditions. For future measurements (unknowns), a linear response will be used based on the line defin

Seite 512 - B.1.8.3 File Example

Section 3. Introduction 3-12

Seite 513 - B.2 Datalogger Data Formats

Appendix F. Calibration and Zeroing The following values of the mode variable give the status of the calibration: 0 No calibration has been performe

Seite 514

Appendix F. Calibration and Zeroing 5. Note that the datalogger automatically sets the mode variable to 2 during the calibration process. 6. Note t

Seite 515 - B.3 Binary Data Value Types

Appendix F. Calibration and Zeroing F.5 Using the Calibration Wizard with Running Programs The LoggerNet Calibration Wizard provides an easy to use

Seite 516 - B.4.4 File Format Convert

Appendix F. Calibration and Zeroing Now select the kind of calibration you wish to perform, which in this case is Multiplier and Offset, and press Ne

Seite 517 - B.5 RTMS Format Description

Appendix F. Calibration and Zeroing The currently measured value for the sensor will be displayed in the next screen. Now place the sensor into the

Seite 518

Appendix F. Calibration and Zeroing After the multiplier and offset have been calculated and set, the ending screen of the Wizard appears. You can c

Seite 519 - CR200, and CR9000

Appendix F. Calibration and Zeroing F.5.3 Using the Wizard to Perform Zeroing Calibrations In the Wizard, select Zero for the type of calibration.

Seite 520 - Programs and Data Storage

Appendix F. Calibration and Zeroing The Current Value box will be yellow during the calibration process. When it finishes, you will see the new val

Seite 521

Appendix F. Calibration and Zeroing Select the sensor you wish to calibrate, press Next. Now you can view the current reading on the sensor to be ca

Seite 522

Appendix F. Calibration and Zeroing F.6 Strain and Shunt Calibration In addition to the FieldCal instruction that performs calibrations on measureme

Seite 523 - C.3 Table Data Overview

Section 4. Setting up Datalogger Networks The EZ and Standard Views of the Setup Screen provide ways to create and maintain the communications link

Seite 524 - C.4 Default Tables

Appendix F. Calibration and Zeroing F-16

Seite 525

Appendix G. Importing Files into Excel Data files saved by LoggerNet can be imported into a spreadsheet program for analysis or manipulation. Instr

Seite 526

Appendix G. Importing Files into Excel Step 2 of 3 From the Delimiters group box, select Comma and Space. The Comma option directs Excel to place ea

Seite 527

Appendix G. Importing Files into Excel Step 3 of 3 A quick look at the columns of data is provided in the Data Preview group box. To complete the i

Seite 528

Appendix G. Importing Files into Excel ([Year]–1900)*365+1+Int(([Year] –1901)/4)+[Day]+Int([HHMM]/100)/ 24+([HHMM]/100-Int([HHMM]/100))*100/60/24+[Se

Seite 529 - D.2.2 Operation

Appendix G. Importing Files into Excel Step 2 of 3 From the Delimiters group box, select Comma and Space. The Comma option directs Excel to place ea

Seite 530

Appendix G. Importing Files into Excel Step 3 of 3 A quick look at the columns of data is provided in the Data Preview group box. Highlight the colu

Seite 531 - D.3 Directory Organization

Appendix G. Importing Files into Excel The quotation marks can be removed by using Excel’s Search and Replace feature. From the Excel menu, select E

Seite 532 - (Program File Directory)

Appendix G. Importing Files into Excel G-8

Seite 534 - E.1.2 Enabling Log Files

Section 4. Setting up Datalogger Networks Subsequent pages are similar. Previous and Next buttons are provided to move through each step of the wiza

Seite 535

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbe

Seite 536

Section 4. Setting up Datalogger Networks Wizard to send a program to a table-based datalogger, the software will already be aware of the data tables

Seite 537

Table of Contents 3.2.11 Optional Client Products Compatible with LoggerNet ... 3-10 3.2.11.1 LoggerNetData ...

Seite 538

Section 4. Setting up Datalogger Networks The number of tabs will vary, based upon the type of device that is selected. Some devices may have only h

Seite 539

Section 4. Setting up Datalogger Networks The contents of the Add Device window will change as each device is added to the network map. Only those

Seite 540

Section 4. Setting up Datalogger Networks To delete a device from the network map select the device and click the Delete button. This will delete t

Seite 541

Section 4. Setting up Datalogger Networks 4.2.3 Renaming Network Devices The names of all of the devices can be changed as desired. Rename a device

Seite 542

Section 4. Setting up Datalogger Networks Extra Response Time – LoggerNet is preconfigured to allow time for responses based on type of device and ba

Seite 543

Section 4. Setting up Datalogger Networks Advanced Call-back Enabled – Enabling call-back tells LoggerNet to watch for a call-back from the datalogge

Seite 544

Section 4. Setting up Datalogger Networks Standard Communications Enabled – Before communication can take place, all devices in the chain must be ena

Seite 545

Section 4. Setting up Datalogger Networks 4.2.4.4 Datalogger Dataloggers have several different tabs. Similar to the serial port, a hardware tab is

Seite 546

Section 4. Setting up Datalogger Networks If you are using LoggerNet Admin or LoggerNet Remote 4.0 and using the Connect Screen to connect to a remot

Seite 547

Section 4. Setting up Datalogger Networks BMP1 Station ID – The address that will be used for the device in the BMP1 network. When adding a new devi

Seite 548

Table of Contents 4.2.5.2.3 Communications Path Considerations ... 4-54 4.2.5.3 Setting Up Scheduled Data Collection ...

Seite 549

Section 4. Setting up Datalogger Networks Apply to Other Stations – This button allows the schedule setup for this datalogger to be copied to other s

Seite 550

Section 4. Setting up Datalogger Networks Stay On Collect Schedule – By default, when LoggerNet has missed a scheduled collection because of some con

Seite 551

Section 4. Setting up Datalogger Networks • Automatically Reset Changed Tables – LoggerNet will reset (delete and recreate) any tables that have cha

Seite 552

Section 4. Setting up Datalogger Networks 4.2.4.4.3 Final Storage Area 1 and 2 Tab (Edlog Dataloggers with Mixed-array Operating System) Mixed-array

Seite 553

Section 4. Setting up Datalogger Networks 01+0109. 02+2002. 03+0038. 04+1639. 05+15.00 06+13.20 07+24.79 08+073.9 09+269.0 10–1.000 01+0109. 02+200

Seite 554 - E.2 CQR Log (RF Link)

Section 4. Setting up Datalogger Networks The individual tables can be highlighted by clicking the table name. The settings on the right side of the

Seite 555 - F.1 Calibration Essentials

Section 4. Setting up Datalogger Networks specify if a timestamp and record number should be included, and whether midnight is specified as 2400 or 0

Seite 556

Section 4. Setting up Datalogger Networks Use Reported Station Name – Enabling this check box will cause the station name from the Status Table to be

Seite 557 - F.3.1 Zeroing

Section 4. Setting up Datalogger Networks Set Station Clock – Press this button to manually set the clock to that of the LoggerNet server. The Allow

Seite 558 - F.3.2 Offset Calibration

Section 4. Setting up Datalogger Networks Delete Files After Retrieval – When this box is selected, the files will be deleted from the datalogger aft

Seite 559 - Control

Table of Contents 5.1.7.2.1 Adding and Removing Values ... 5-15 5.1.7.2.2 Display Options ...

Seite 560 - Calibration

Section 4. Setting up Datalogger Networks configurations. When the Edit Modem Database button is selected, the reset and initialization strings for

Seite 561

Section 4. Setting up Datalogger Networks the delay specified. The amount of time to delay is in milliseconds so a 5-second delay would be entered a

Seite 562 - Programs

Section 4. Setting up Datalogger Networks If you are using LoggerNet Admin or LoggerNet Remote 4.0 and using the Connect Screen to connect to a remot

Seite 563 - and press Next

Section 4. Setting up Datalogger Networks Advanced Use F Command – The “F” command forces the baud rate to 9600. In the modem enabled (ME) state, th

Seite 564

Section 4. Setting up Datalogger Networks For Example: If: RF Polling Interval = 5 minutes RF Poll Offset = X Computer Offset = 4 minutes 47 s

Seite 565

Section 4. Setting up Datalogger Networks When the device is connected in the Connect Screen and the time limit approaches, a dialog box is displayed

Seite 566

Section 4. Setting up Datalogger Networks Delay Hangup – The amount of time, in seconds and milliseconds, that LoggerNet should delay before hanging

Seite 567

Section 4. Setting up Datalogger Networks Adjusted Server Date/Time – Displays the date and time for the computer on which the LoggerNet server is ru

Seite 568

Section 4. Setting up Datalogger Networks LoggerNet to use a default verify interval of 2.5 times the beacon interval. If the beacon interval is als

Seite 569

Section 4. Setting up Datalogger Networks When the device is contacted on a schedule, communication with the device will be terminated once this time

Seite 570

Table of Contents 6.4.1 Selecting the PakBus Network to View ... 6-17 6.4.2 Dynamic and Static Links ...

Seite 571 - Step 1 of 3

Section 4. Setting up Datalogger Networks 4.2.4.13 MD9 Remote The MD9 remote is the MD9 modem device that is connected to the datalogger at the fiel

Seite 572 - Step 2 of 3

Section 4. Setting up Datalogger Networks If you are using LoggerNet Admin or LoggerNet Remote 4.0 and using the Connect Screen to connect to a remot

Seite 573 - Step 3 of 3

Section 4. Setting up Datalogger Networks When the device is contacted on a schedule, communication with the device will be terminated once this time

Seite 574

Section 4. Setting up Datalogger Networks Maximum Time On-Line – This field is used to define a time limit for maintaining a connection to the device

Seite 575

Section 4. Setting up Datalogger Networks 4.2.4.16 Generic Modem The Generic Modem is used to set up any device in the communications network whose

Seite 576

Section 4. Setting up Datalogger Networks Hardware Tab, Advanced Extra Response Time – In this field, specify the additional time that LoggerNet shou

Seite 577

Section 4. Setting up Datalogger Networks PakBus Graph can be used to visually monitor and retrieve settings from devices in a PakBus network. Refer

Seite 578

Section 4. Setting up Datalogger Networks If you are using LoggerNet Admin or LoggerNet Remote 4.0 and using the Connect Screen to connect to a remot

Seite 579

Section 4. Setting up Datalogger Networks TCP Password – This is a password that is used to control IP access to a datalogger. Passwords are assigne

Seite 580

Section 4. Setting up Datalogger Networks 4.2.4.19 PakBusPort HD This virtual device is used to facilitate communication with a PakBus datalogger in