Section 10. Utilities Installed with LoggerNet
elapsed since the last attempt, LoggerNet will immediately try to perform a
poll. In some cases, this may not be the desired behavior. Selecting the Stay
On Schedule check box will cause LoggerNet to always wait until the next
even Normal Poll Interval to perform a poll.
Base Date Enter a date and a time that the first polling attempt for the device
should occur. If the date and time reflected by these fields has already passed,
polling will be attempted immediately when the schedule is enabled.
Normal Poll Interval Enter the interval on which data should be collected
from the device.
Primary Retries IntervalEnter the interval at which primary retries will
take place. The collection schedule will switch to primary retries when a
communication or other error prevents a normal” collect attempt from being
completed.
Max Primary Retries Enter a value for the maximum number of data
collection attempts that should be made using the Primary Retries Interval.
Once the number of primary retries is exhausted, data collection will be
attempted on the Secondary Retries Interval if it is enabled. Otherwise, data
collection attempts will continue to be made on the Normal Poll Interval.
Secondary Retries Interval Enter the interval at which secondary retries
will take place.
Do Secondary RetriesSelect this check box to enable secondary retries
when primary retries are exhausted. If this checkbox is not checked, the
collection schedule for the device will return to the Normal Poll Interval after
primary retries are exhausted even if none of those retries succeeded.
Tables to Collect This check list box specifies shows a check box for each
tablethat can be collected from the RWIS station that specifies whether that
table will be polled as part of scheduled collection. For more information on
available tables, refer to the online help.
File Open ModeSpecify, for the selected table, the method for writing the
table data to an output file when it is polled. Options for this control include
the following:
do not create No file will be created for the selected table.
append to existingIf a data file already exists for the selected
table, new data records will be appended to the end of that file.
Otherwise, a new data file will be created.
overwrite existingAny existing data file for the selected table will
be overwritten each time that a new record is collected.
unique name each time A new data file will be created each time
that a record is collected for the specified table. The name of this file
will be unique and based, in part, on the timestamp for the record.